Model UT81B: OPERATING MANUAL
Figure 3-3. µA Range Measurement
l
To measure ACµA or DCµA currents, set up the
Meter as Figure 3-3 and proceed as follows:
1. Insert the red test lead into the µmA terminal and
black test lead into the COM terminal.
2. Set the rotary switch to µA
.
3. Connect the test lead in series with the return circuit
to be tested.
4. The measured value shows on the display.
5. Press MODE button to toggle between Multimeter
mode and Scope mode.
6. Press F1 to toggle between AC and DC current
measurement.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the UNI-T UT81B and is the answer not in the manual?

UNI-T UT81B Specifications

General IconGeneral
BacklightYes
Product typeDigital multimeter
Frequency range0.01 - 10000 kHz
AC current range0.4 - 10 A
AC voltage range4 - 750 V
DC voltage range0.4 - 1000 V
Dimensions (WxDxH)100 x 48 x 200 mm
Battery voltage1.5 V
Weight and Dimensions IconWeight and Dimensions
Weight498 g