SCUBAPRO MK 25/MK 20 First Stages
2003 SCUBAPRO
Important note
: The following information is not designed to be a complete training guide for servicing the listed SCUBAPRO regulators. All SCUBAPRO
technicians are required to attend an annual service training program to insure safe handling and servicing of SCUBAPRO products. All SCUBAPRO technicians
must be employed by an authorized SCUBAPRO facility.
4
Remove the yoke nut and cap from the
first stage.
Loosen the star clip and remove the
filter.
Remove the yoke nut o’ring.
6mm
For DIN Regulators
Remove the filter retainer, spring, filter,
DIN adapter and o’ring.
Loosen the DIN fitting using a 6mm hex
wrench.
Remove the end cap.
Loosen the seat retainer using a
properly sized wrench while holding the
first stage with a first stage handle.