D-303404 GSD-442 PG2 Installation Instructions 1
GSD-442 PG2
PowerG Wireless Carbon Monoxide (CO) Detector
Installation Instructions
1. INTRODUCTION
The Wireless PowerG Two-way Carbon Monoxide (CO) Detector is designed to monitor the CO gas level in residential dwellings and
give early warning before potentially dangerous levels exist. The CO alarm is transmitted to the PowerMaster control panel and
presented on its display.
The CO gas is considered to be a highly dangerous poisonous gas because it is colorless, odorless, tasteless and very toxic. Presence
of CO gas inhibits the blood's capacity to transport oxygen throughout the body, which can eventually lead to brain damage. CO gas is
produced by incomplete combustion of fuels (such as natural gas, propane, heating oil, kerosene, coal, charcoal, gasoline or wood) that
can occur in any device that depends on burning for energy and heat (such as furnaces, boilers, room heaters, hot water heaters, stoves,
grills and in any gasoline powered vehicle or engine).
Before CO harmful level is reached, the detector's internal buzzer beeps sound periodically
and the detector's red LED flashes. In this condition, the buzzer sound can be stopped for 6
minutes by pressing the TEST/MUTE switch. It will not correct the CO gas problem, but will
temporarily silence the buzzer while you correct the problem. After 6 minutes, the detector
restarts alarm if the CO level remains high.
The detector provides low battery and detector end-of-life indications.
Caution: The detector expiry date is stamped on the detector. After the expiry date, the
detector should not be used - do not wait for end-of-life indication!!
The detector is continuously self-tested and has a TEST button that enables the user to test
the detector anytime.
Note: The TEST/MUTE switch functions as TEST switch (in normal operation) or as MUTE
switch (in alarm condition).
The tamper switch actuator (Figure 3), is pressed against the bracket when the unit is
attached to the bracket. Removal of the unit from the bracket causes the switch contacts to
open, creating a tamper event, which is reported by the transmitter to the alarm system
control panel.
A
B
C
A. Alarm (red) LED
B. Battery (green) / Fault (yellow) LED
C. TEST / MUTE button
Figure 1 - General View
2. PREPARATIONS
2.1 Disassembly
1
2
A
B
1. Hold the bracket with one hand
2. Rotate the detector as shown and pull it from the bracket
A. Bracket
B. Detector
Figure 2. Separating the Detector from Its Bracket
2.2 Enrollment
Refer to the PowerMaster Installer Guide and follow the procedure under the "02:ZONES/DEVICES" option of the Installer Menu. A general
description of the procedure is provided in the following flow chart.
Step 1 Step 2 Step 3 Step 4 Step 5
Enter the Installer menu
and select
02:ZONES/DEVICES
Select "ADD NEW
DEVICE" Option
Enroll the device or Enter
the device ID
See Note
Select the desired Zone
Number
Configure the
Location Parameter
means scroll and select
Note:
i) Insert the battery (see Figure 3) to enroll the gas detector.
-or-
ii) Key in the device ID of the gas detector and at a later stage, when the installation makes possible, insert the battery.
Z
0
7.
L
OCATION
ID No. 220
-
X
XXX
Z
07:
G
AS Sensor
E
NTR ID:XXX
-
X
XXX
NROLL NOW or
A
DD NEW DEVICES
0
2.ZONES/DEVICES

Other manuals for Visonic GSD-442 PG2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Visonic GSD-442 PG2 and is the answer not in the manual?

Visonic GSD-442 PG2 Specifications

Operating Environment IconOperating Environment
operating temperature0°C to 40°C
operating environmentIndoor
Battery IconBattery
battery type9V lithium battery or alkaline battery
Weight and Dimensions IconWeight and Dimensions
weight180 g
dimensions127 x 40 mm