8.
THERMOSTART
(Optional)
(1
Specifications
Specifications
SH10002 LHitachil
magnetic
valve
type
Votage
Current flow
(2)
Description of the Thermostart
The thermostan is a starting aid for use in low
ambient temperatures.
It
ignites and burns fuel
in the intake manifold to warm the air intake and
improve starting qualities. Thethermostart, unlike
glow plugs,
is
not exposed to the combustion heat
-
of the engine during operation and therefore pro-
vides outstanding durability, and since
its
elec-
tricity requirement is lower than that of glow
plugs, the load on the battery
is
reduced.
Fuel
--
\
Ball
valve
t eater
coil
Terminal
a) Thermostan switch
is
set to ON. This
activates the heater coil.
b) Valve stem moves. This opens the ball
valve.
c)
Fuel flows through ball valve, and volatil-
izes because of heat from heater coil.
e)
Setting thermostart switch to OFF posi-
tion will switch off the electricity and the heat-
er will cool off. This will close the ball valve.
f)
Fuel will cease to flow. Fuel is stored in
header tank, and
is
fed to thermostart plug by
gravity.
(3)
Using the Thermostart
a)
Throttle lever
is
set to STOP position.
b)
Decompression lever
is
operated.
C)
Clutch pedal
is
depressed, and starter mo-
tor is operated for five seconds (until lube oil
indicating light goes out).
d)
Restore decompression lever to position
providing compression.
e)
Open the throttle about halfway.
f) Press the thermostart switch for
5
-
10
seconds. OR
i) Turn the main switch to the
"TS"
position for
5
-
10
seconds.
ii)
Then turn the starter motor.
g)
As soon as the engine starts up, switch off
the thermostart, and of course, remove your
hand from the starter key switch (the main
switch will automatically move from the
START to the ON position).
Main Switch
d)
Volatilized fuel is ignited by ignitor.