c) valvular tap
a) minimum
regulation
screw
b) normal tap
Fig. 8
Fig. 9
MAINTENANCE
Periodically control the state of conservation and
efficiency of the gas tube and, if present, the
pressure regulator; in case of irregularity do not
attempt to repair, but substitute the damaged part.
To guarantee good functioning and security the
gas regulation taps should be periodically
greased.
The periodic lubrification of the taps must
be carried out by qualified personnel who
should also be contacted in case
irregularities are encountered in the
functioning of the apparatus.
FO 1045
TYPE TYPE NOZZLE NOMINAL REDUCED
NOMINAL
OF GAS OF BURNER MARKS THERMAL THERMAL
PRESSURE
1/100 mm CAPACITY CAPACITY kPa
MJ/h MJ/h
Rapid (large) 140 10,00 2,34
Semi-rapid (medium) 111 6,12 1,51 1,0
Auxiliary (small) 89 3,60 0,90
Rapid (large) 88 9,72 2,34
Semi-rapid (medium) 71 6,12 1,51 2,75
Auxiliary (small) 55 3,60 0,90
NATURAL
GAS
(methane)
L.P.G.
GAS