9
 0HDVXUHIURPUDQJHWRSWRKRRGERWWRPDQGPDUNOLQH$
´PLQLPXPIURPUDQJHWRS
 3OXPDQGPDUNFHQWHUOLQH
 0DUNPRXQWLQJKHLJKWOLQH%´IURPOLQH$
0DUNPRXQWLQJVSUHDGIURP&/RQOLQH%)URP&/WROHIW
PRXQWPDUN´)URP&/WRULJKWPRXQWPDUN´
 )DVWHQ[´VFUHZVLQWRVWXGVRQOLQH%'RQRW
fasten screws all the way. Note: wood blocking may need
to be added behind the drywall if no studs are present.
Wall anchors may also be used but check local codes
for compliance. Failure to use suitable wall anchors
and screws to hold the weight of the hood could result
in personal injury or damage to cooking surface or
counter.
 +DQJKRRGRQWRVFUHZVDQGKDQGWLJKWHQ),*$8VH
WKHODVW[´VFUHZVWRIXUWKHUVHFXUHWKHKRRGWRWKH
wall from inside the hood.
&HQWHUDQGDWWDFKGXFWFRYHUEUDFNHWWRZDOOEHORZFHLOLQJRU
VRႈWXVLQJ[´VFUHZV
8. Install electrical.
,QVWDOOGXFWZRUNDQGVHDODOOMRLQWVZLWKFHUWL¿HGGXFWWDSH
3RZHUXSKRRGDQGFKHFNIRUOHDNVDURXQGGXFWWDSH
11. Place telescopic duct covers onto hood and extend inner
WRSGXFWFRYHUXSZDUGVDQGVHFXUHWRGXFWFRYHUEUDFNHW
XVLQJ0[VFUHZV
*If using hood in recirculating mode you must secure air
GLYHUWHUSODWHRQWRZDOOEHIRUHLQVWDOOLQJGXFWZRUNDQGGXFW
covers. Turn to page10 for more details.
A
B
C/L
12 1/4"
C/L
26" min
fig. A
Duct Cover Bracket
2"3-1/2"
CAUTION: At least two installers are
required due to the weight and size of the
hood.
!
WARNING: Electrical wiring must be done by a qualified person(s) in
accordance with all applicable codes and standards. This range hood must be
properly grounded. Turn off electrical power at service entrance before wiring.
!
Installation – Mounting the Hood
FIG. A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zephyr Ombra and is the answer not in the manual?