SECTION: 2.65.013
FM3124
0320
Supersedes
0918
TECHNICAL DATA SHEET
MODEL 508 12-VOLT BACKUP
Submersible Sump Pump System
Product information presented
here reects conditions at time
of publication. Consult factory
regarding discrepancies or
inconsistencies.
© Copyright 2020 Zoeller
®
Co. All rights reserved.
502-778-2731 | 800-928-7867 | 3649 Cane Run Road | Louisville, KY 40211-1961 | zoellerpumps.com
CONTROLLER
The Aquanot
®
Fit 508 with Z Control
®
technology is a premium high
performance, self-testing internet-connected battery backup pump
system.
PUMP
12 volt, highly efcient, non-corrodible pump construction.
Supplied with 9' (2.7 m) leads.
Legs allow free-standing installation
Quick disconnect discharge
Aluminum seal pocket and cooling plate
Integrated check valve
CONTROLLER
The Aquanot
®
Fit DC Controller keeps the battery charged. The
controller has many built-in features such as:
Monitors the switches,runs the pump
Performs Self-testing diagnostics
Communicates with the Z Control
®
Cloud; receives
commands from user through Cloud such as "Silence",
"Reset", "Test", and many conguration changes
7 amp
BUTTONS
Alarm Silence/Reset - press to silence alarms. Press and hold
for three seconds to reset alarms.
Test - Press to initiate pump test
SWITCHES
Reliable, vertical oat switch for adjustable operation.
High water reed sensor provides high water signal and
redundant pump run.
BATTERY CASE
The included battery case will accommodate maximum battery
dimensions of 13" (330 mm) L x 7-1/2" (191 mm) W x 9-1/2" (241
mm) H and ts all group size 27, 29 and 31 batteries. Made from
non-corrodible polyethylene. To use multiple batteries, order extra
battery case with hookup wire (P/N 007861).
FITTINGS
An integrated DC pump discharge check valve, additional thread-in
AC pump check valve, tee, and adapter are included.
Connection fault
Power outage/restored
Pump activation
ALERTS
Pump cycled
High water
Battery fault
Switch fault
Pump fault
Aquanot
®
Deep-cycle Battery (purchase separately)
P/N 10-1450 - AGM (shown)
P/N 10-0761 - Wet
Aquanot
®
Fit 508 system
Patent No. D740329
AQUANOT
®
FIT
Solid Flashing Off
System
Ready
No Faults (Green)
AC off with no
faults (Green)
--
Battery
Charged (Green)
Low Battery (Red) No AC Power
Charging (Yellow)
Bad Battery (Red)
DC pump
Pump Ran
(Yellow)
Pump Running
(Yellow)
--
Pump Fault (Red)
Float
Status
High Water (Red) Float Fault (Red) --
Z Control Connected Searching
Broadcasting
SSID or
Dormant

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zoeller AquaNot Fit 508 and is the answer not in the manual?

Zoeller AquaNot Fit 508 Specifications

General IconGeneral
BrandZoeller
ModelAquaNot Fit 508
CategoryWater Pump
LanguageEnglish

Related product manuals