SECTION: 2.65.013
FM3124
0320
Supersedes
0918
TECHNICAL DATA SHEET
MODEL 508 12-VOLT BACKUP
Submersible Sump Pump System
Product information presented
here reects conditions at time
of publication. Consult factory
regarding discrepancies or
inconsistencies.
© Copyright 2020 Zoeller
®
Co. All rights reserved.
502-778-2731 | 800-928-7867 | 3649 Cane Run Road | Louisville, KY 40211-1961 | zoellerpumps.com
CONTROLLER
The Aquanot
®
Fit 508 with Z Control
®
technology is a premium high
performance, self-testing internet-connected battery backup pump
system.
PUMP
• 12 volt, highly efcient, non-corrodible pump construction.
Supplied with 9' (2.7 m) leads.
• Legs allow free-standing installation
• Quick disconnect discharge
• Aluminum seal pocket and cooling plate
• Integrated check valve
CONTROLLER
The Aquanot
®
Fit DC Controller keeps the battery charged. The
controller has many built-in features such as:
• Monitors the switches,runs the pump
• Performs Self-testing diagnostics
• Communicates with the Z Control
®
Cloud; receives
commands from user through Cloud such as "Silence",
"Reset", "Test", and many conguration changes
• 7 amp
BUTTONS
• Alarm Silence/Reset - press to silence alarms. Press and hold
for three seconds to reset alarms.
• Test - Press to initiate pump test
SWITCHES
• Reliable, vertical oat switch for adjustable operation.
• High water reed sensor provides high water signal and
redundant pump run.
BATTERY CASE
The included battery case will accommodate maximum battery
dimensions of 13" (330 mm) L x 7-1/2" (191 mm) W x 9-1/2" (241
mm) H and ts all group size 27, 29 and 31 batteries. Made from
non-corrodible polyethylene. To use multiple batteries, order extra
battery case with hookup wire (P/N 007861).
FITTINGS
An integrated DC pump discharge check valve, additional thread-in
AC pump check valve, tee, and adapter are included.
• Connection fault
• Power outage/restored
• Pump activation
ALERTS
• Pump cycled
• High water
• Battery fault
• Switch fault
• Pump fault
Aquanot
®
Deep-cycle Battery (purchase separately)
P/N 10-1450 - AGM (shown)
P/N 10-0761 - Wet
Aquanot
®
Fit 508 system
Patent No. D740329
AQUANOT
®
FIT
Solid Flashing Off
System
Ready
No Faults (Green)
AC off with no
faults (Green)
--
Battery
Charged (Green)
Low Battery (Red) No AC Power
Charging (Yellow)
Bad Battery (Red)
DC pump
Pump Ran
(Yellow)
Pump Running
(Yellow)
--
Pump Fault (Red)
Float
Status
High Water (Red) Float Fault (Red) --
Z Control Connected Searching
Broadcasting
SSID or
Dormant