EasyManuals Logo
Home>ABB>Relays>CO

ABB CO User Manual

ABB CO
18 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #13 background imageLoading...
Page #13 background image
I
.
L
.
41
-
103
H
STAT
10
«
BuB
1
CO
RELAY
(
FNONT
VIEW
)
2
3
3
01
52
S
l
>
co
I
-
4
-
(
TIMER
STOPS
)
{
MEN
AUK
.
(
RELAT
CONTACT
(
OPENS
r
°
L
cP
f
O
O
r
.
G
r
TO
TIMER
uC
_
o
o
c
o
i
©
.
<
&
.
©
_
©
]
(
L
©
©
©
C
8
)
®
i
STOP
)
)
TO
(
TIMER
STARTS
?
TIMER
(
VHEN
SWITCH
)
START
(
“
S
'
CLOSES
)
AUK
.
RELAY
r
-
J
52
-
2
rc
b
‘
H
O
(
oi
)
—
^
T
V
cs
H
PH
.
2
^
RESISTANCE
LOAD
SNITCH
AMIETER
•
S
’
V
120
VOLTS
W
CYC
.
52
-
3
PH
.
3
A
^
A
/
c
si
Q
-
oi
,
H
2
Sc
/
/
?
7
183
A
214
Fig
.
10
.
Diagram
of
Test
Connections
for
the
Circuit
Opening
CO
Relay
in
the
Type
FT
-
21
Case
1
2
3
DEVICE
NUMBER
CHART
51
*
QVERCURRENT
RELAT
.
TYPE
CO
CS
“
DE
-
ION
CONTACTOR
SWITCH
IN
TYPE
CO
RELAY
01
-
OPERATION
INDICATOR
IN
TYPE
CO
RELAY
52
*
POWER
CIRCUIT
BREAKER
TC
-
BREAKER
TRIP
COIL
SETTINGS
CO
UNIT
Sub
1
183
A
213
The
overcurrent
unit
settings
can
be
defined
either
by
tap
setting
and
time
dial
position
or
by
tap
setting
and
a
specific
time
of
operation
at
some
current
multiple
of
the
tap
setting
(
e
.
g
.
4
tap
setting
,
2
time
dial
position
or
4
tap
setting
.
0.6
seconds
at
6
times
tap
value
current
)
.
Fig
.
11
.
ExternaI
Schematic
of
the
Circuit
Opening
Type
CO
Relay
for
Phase
Overcurrent
Protection
on
a
Three
Phase
System
Chassis
operating
shorting
switches
on
the
case
will
short
the
secondary
of
the
current
trans
-
former
.
The
taps
should
then
be
changed
with
the
relay
outside
of
the
case
and
then
re
-
inserted
into
the
case
.
To
provide
selective
circuit
breaker
operation
,
a
minimum
coordinating
time
of
0.3
seconds
plus
circuit
breaker
time
is
recommended
between
the
relay
being
set
and
the
relays
with
which
coordi
-
nation
is
to
be
effected
.
INSTANTANEOUS
RECLOSING
The
connector
screw
on
the
terminal
plate
above
the
time
dial
makes
connections
to
various
turns
on
the
operating
coil
.
By
placing
this
screw
in
the
various
terminal
plate
holes
,
the
relay
will
respond
to
multiples
of
tap
value
currents
in
accordance
with
the
various
typical
time
-
current
curves
.
The
factory
adjustment
of
the
CO
unit
contact
provides
a
contact
follow
.
Where
instantaneous
circuit
breaker
reclosing
will
be
initiated
upon
the
closure
of
the
CO
contact
,
this
contact
follow
must
be
eliminated
by
loosening
the
stationary
contact
mounting
screw
,
removing
the
contact
plate
and
then
replacing
the
plate
with
the
bent
end
resting
against
the
contact
spring
.
With
this
change
and
the
contact
mounting
screw
tightened
,
the
stationary
contact
will
rest
solidly
against
its
backstop
.
CAUTION
Since
the
tap
block
connector
screw
carries
oper
-
ating
current
,
be
sure
that
the
screw
is
turned
tight
.
IN
ORDER
TO
AVOID
OPENING
CUR
-
RENT
TRANSFORMER
CIRCUITS
WHEN
CHANGING
TAPS
UNDER
LOAD
,
THE
RELAY
MUST
BE
FIRST
REMOVED
FROM
THE
CASE
.
O
DE
-
ION
CONTACTOR
SWITCH
(
CS
)
No
setting
is
required
on
this
unit
.
13
Courtesy of NationalSwitchgear.com