32 | Terra 53/23 Charging Station User and Operator Guide version 1.0
In idle mode and switched on, the charger consumes around 70-80 watts of power.
A 1000 Watt heater is built into the charger for climate control inside the cabinet. This keeps the
components functioning within temperature and humidity specifications and prevents
condensation. This heater will switch on to full power when:
- The temperature inside the cabinet is below -20°C
- The humidity is above 90% relative humidity.
The heater switches off when:
- The inside of the charger is heated to -12°C
- The humidity is below 80%.
4.7 Preventive maintenance
The charger must be inspected and serviced yearly by a certified technician.
5. Compliance
Conformity with the relevant community harmonization legislation
EMC Directive - No. 2014/30/EU
Low Voltage - 2014/35/EU
RED Directive - No. 2014/53/EU
MID Directive No. 2014/32/EU
Conformity with the following harmonized standards
Emission: EN 61000-6-3 (2007) + A1 ; EN 61000-6-4 (2007) + A1
Immunity: EN 61000-6-1 (2007) ; EN 61000-6-2 (2005)
LVD: EN 61851-1 (2011) + EN 61851-23 (2014)
EN 62196-1 (2012)
RED: EN 301 908-2 V11.1.2 (2017) ; EN 301 511 V12.5.1 (2017)
EN 300 330 V2.1.1 (2017) ; EN 50364 (2001)
MID: EN 50470-1 (2006); EN 50470-3 (2006)
Conformity to the metrology directives:
MessEG
MessEV
Product compliant to the REA DOCUMENT 6A