Take 2x4 cabinets for example; following are the instructions for power and signal
cable connection method:
Power Cable Wiring
Total power for 8 cabinets with size 1440x288mm each is:
8x1.440x0.288x480w=1.6kw, arranged in 2x4 with 2 cabinet columns, and 4 cabinets
for each column connected to power supply in series. In this case use a 3X1.5mm2
power cable to connect from the distribution box or socket to the bottom of the
cabinet.
Network Cable Wiring
The network cable is connected from up to down in "S" shape. Please calculate the
resolution as per load range. Please note that the load pixel range for each network
interface is not more than 650,000 pixels.