38 39
6. Technical data
The Secuquick softline meets the safety requirements of the European Pressure Equipment Directive
2014/68/EU. The Secuquick softline, together with the approved pots, underwent a safety test at the
TUV (Technischer Überwachungsverein).
Model details with the pressure specifications are engraved in the bottom cover: Operating pressure
while cooking
(= PC) 80 kPa (0.8 bar); highest permissible pressure (= PS) 300 kPa (3.0 bar).
7. AMC Customer service
If you have any questions or suggestions, please contact AMC Customer Service. Spare parts can
also be ordered from here. Have the model number and diameter of the Secuquick softline ready for
accurate product identification. Both specifications can be found on the inside of the bottom cover.
AMC PREMIUM COOKING SYSTEM
Secuquick softline 4300 –
20/24 cm – PS 300kPa – PC 80kPa – 0000
5. What to do when...
The Secuquick softline cannot be closed
The Secuquick softline is set on the pot, but the knob cannot be turned all the way.
Troubleshooting:
Press on the Visiotherm with one hand while turning the knob. If this is still not possible, carry out
the following steps:
 Check that the knob can be turned easily when the Secuquick softline is taken o the pot. If
this is not possible, check that the Secuquick softline is correctly assembled (bell nut firmly
tightened).
 Check whether the cover closure is dirty or whether a foreign body is caught in it; clean if nec-
essary.
 Check that the sealing ring is correctly inserted.
 Check that the pouring rim of the pot is clean and undamaged.
The Secuquick softline cannot be opened
The Secuquick softline cannot be opened with the rotary knob. It moves briefly and then sticks. The pot
may still be under pressure.
Troubleshooting:
Depressurize the pot. Observe precautionary measures. Once the pot is no longer under pressure:
 Turn the knob all the way back to the „closed“ position and try again.
 Press the Secuquick softline down while turning the knob.
No or too little pressure in the pot
The temperature indicator on the Visiotherm S does not reach the first Soft window or the first Turbo win-
dow.
Troubleshooting:
 Check that the Secuquick softline is closed correctly.
 Check that the correct cooking zone diameter is selected.
 Check that the highest level is set on the cooking zone.
 Check whether there is sucient liquid in the pot.
Continuous steam venting
Steam is continuously escaping during operation.
Troubleshooting:
 Check that the sealing ring is correctly inserted.
 Check that the bell nut is firmly tightened.
 Check that all valves and seals are correctly seated, clean and undamaged.
Sudden venting of steam
Steam suddenly escapes to the sides from between the bottom and top covers.
Troubleshooting:
Stop using the Secuquick softline and contact AMC customer service.
The pot has been overheated and the operating pressure valve has failed.
A safety valve has been triggered.
EN
AMC International
Alfa Metalcraft Corporation AG
Buonaserstrasse 30
6343 Rotkreuz
Switzerland
+41 41 - 799 52 22
info@amc.info
Customer service
21

Other manuals for AMC Secuquick softline

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AMC Secuquick softline and is the answer not in the manual?

AMC Secuquick softline Specifications

General IconGeneral
BrandAMC
ModelSecuquick softline
CategoryCooking Equipment
LanguageEnglish

Related product manuals