FAULTFINDING
FAULT
POSSIBLE
CAUSES
REMEDY
NO
HOT
WATER
FLOW
REDUCED
FLOW
RATE
WATER
FROM
HOT
TAPS
IS
COLD
DISCHARGE
FROM
PRESSURE/
TEMPERATURE
RELIEF
VALVE
DISCHARGE
FROM
EXPANSION
VALVE
1)
Mains
cold
water
supply
shut
off
2)
Line
strainer
blocked
3)
Cold
Water
Combination
valve
fitted
incorrectly
1)
Low
mains
water
pressure
2)
Line
strainer
partially
blocked
3)
Size
of
service
pipe
too
small
1)
Direct
immersion
heater
is
not
switched
on
2)
Direct
thermal
cut-out
has
operated
3)
Boiler
programmer
set
to
central
heating
only
(Indirect
models)
4)
Boiler
is
not
functioning
(Indirect
models)
5)
Indirect
thermal
cut-out
has
operated
6)
Motorised
valve
jammed
or
not
wired
correctly
(Indirect
models)
1)
Pressure
above
7
bar,
failure
of
pressure
reducing
valve.
Temperature
above
90®C
failure
of
thermal
control
1)
Continually.
Pressure
reducing
valve
faulty
2)
When
heater
is
heating.
Faulty
expansion
vessel
or
lost
charge
3)
Back
feed
of
high
mains
pressure
via
mixer.
Check
and
open
Isolating
and/or
stop
valve.
Check
water,
Local
Water
Authority
Turn
off
mains
water
supply,
remove
line
strainer
and
clean
Check
direction
of
flow
arrows
on
valve,
refit
in
.
correct
position
if
necessary
Check
pressure,
consult
Local
VVater
Authority
If
necessary
Turn
off
mains
water
supply,
remove
line
strainer
and
clean
Increase
to
size
stated
on
page
9
Check
immersion
heater,
switch
on
if
necessary
Test
thermostat
operation
and
wiring,
if
faulty,
correct/replace.
Reset
cut-out
Check
switch
on
domestic
hot
water
if
necessary
Check
boiler
operation,
if
fault
suspected
consult
manufacturer's
instructions
Test
thermostat
operation
and
wiring,
if
faul^,
correct/replace.
Reset
cut-out
Check
wiring
and
operation
of
motorised
valve
correct/
replace
as
necessary
Shut
down
boiler
or
immersion
heater.
Check
pressure
reducing
valve
and
thermal
controls.
Replace
If
necessary
Check
pressure
from
valve.
Replace
if
over
3.5
bar
Check
charge
of
vessel.
Re
charge
vessel
to
3.5
bar
or
match
Incoming
mains
pressure
replace
If
necessary
Service
/
replace
mixer
WATER
HAMMER
1)
Expansion
Vessel
fitted
vertically.
2)
Pipework
not
secure
Ensure
vessel
is
fitted
horizontally
or
connection
at
top.
Clip
pipework
3)
Jumpers
on
taps
loose
Replace
tap
jumpers

Other manuals for Ariston Classico HE STD 150

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ariston Classico HE STD 150 and is the answer not in the manual?

Ariston Classico HE STD 150 Specifications

General IconGeneral
BrandAriston
ModelClassico HE STD 150
CategoryWater Heater
LanguageEnglish

Related product manuals