COMMISSIONING
Gas setting table
Gas Changeover
Theappliancemaybeadjustedsothatitmaybeused
withLiquidGas(G30/G31)insteadofmethanegas(G20)
or vice-versa.The adjustmentmustbeperformedbya
QualiedTechnicianusingthespecialKit.
FAST R X ONM 11 EU
FAST R X ONM 14 EU
G20 G30 G31 G20 G30 G31
lowerWobbeindex
(15°C,1013mbar)
MJ/m
3
45,67 80,58 70,69 45,67 80,58 70,69
Gas inlet pressure mbar
20 29 37 20 29 37
GasBurnerPressuremax mbar 11,4 24,8 31,8 13,4 27,2 34,8
GasBurnerPressuremin mbar 2 5,3 6,7 2,2 4,6 5,65
MainBurnerjets nr. 12x2 14x2
Øburnerjets mm 0.85*24 0.5*22/0.47*2 0.85*24 0.5*24/0.48*4
Max/minconsumption
(15°C,1013mbar)(G.N.=m
3
/h)(LPGkg/h))
max 2,26 0,648 0,827 2,83 0,804 1,035
min 0,88 0,284 0,368 1,084 0,313 0,398