EasyManuals Logo
Home>Ariston>Water Heater>STD 100 DIRECT

Ariston STD 100 DIRECT User Manual

Ariston STD 100 DIRECT
15 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #14 background imageLoading...
Page #14 background image
Basic Boiler List
Baxi Bermuda range
Boston RS and OF range
Glowworm Complheat
Hideaway range 65 - 80
Ultimate 40 - 80
30B - 80B, 30CF - 60CF
Halstead Buckingham range
Potterton Kingfisher range
Statesman range (oil fired)
Caradon Ideal Classic range
Mexico Ssper range
Mexico Slimline range
Newflame Boilers Backboiler range
Condensing Boiler List
CARADON IDEAL Minimiser FF30 - FF80 L E N
GLOWWORM Energysaver (Remove link SL-9) PL SL E N L
KESTON L E N
POTTERTON Envoy 30F - 80F PL SL E N L
refer to
VAILLANT VU 186, 226 manufacturers
instructions
Boiler Connections
2 Motorised values 2 way (see fig. 11) 9 10 3 2 1
1 Motorised value 3 way (see fig. 12) 9 8 3 2 1
Pump Connections
2 Motorised values 2 way (see fig. 11) 9 3 2
1 Motorised value 3 way (see fig. 12) 9 3 2
- 27 -
FIG. 12
SCHEME OF ELECTRICAL CONNECTIONS WITH MOTORISED VALVE 3 WAY
V4043A
MID. POS. VALVE
WHITE
5
BLUE
2
GREY
7
ORANGE
8
GREEN/YELLOW
3
Honeywell ST 699B 1002
76 3 NL
Link L-5-8
ST 6400/ST 6300 1 3 4 N L
ST 6200 3 4 N L
Drayton Tempus 7 1 3 4 N L
Horstmann 425, 525, 527
31 4E NL
Link L-2-5
Landis & Gyr RWB2
13 4 NL
Glowworm Mastermind
Landis & Gyr RWB20
13 4 NL
Microgyr
Potterton Miniminder 1 3 4 N L
Potterton EP2000/3000 - 1 3 4 N L
Link L-5 EP2001/3001
Randall 102/102 E 1 2 E 5 6
Link 3-6
Randall 4033
54 2E 76
Link 1-6
Randall 701, 702
43 1E NL
Link L-6-5
Sangamo M5 1 8 E 4 3
Link 1-6
Sangamo 410 Form 1
21 8E 43
Link 3-6
PROGRAMMER
764321
Pegler Sunvic
12 5E NL
SP 50/100 (Link L-3)
Switchmaster
31 4 NL
Symphony, Sonata
Switchmaster 400, 600 3 1 N L
SWITCHMASTER 805, 900
43 1 NL
Sunvic ET 1451
87 4E 12
Link 2-3-6
Sunvic DHP 2201 8 6 3 E 1 2
Towerchron FP
86 10 21
Link 1-5/4-7-9
Towerchron MP
610 21
Link 1-4/6-11
Towerchron 2000 HW HW HTG
NL
OFF ON ON
ACL LS522, LS722 1 3 4 N L
Randall 922, 972
13 6E NL
Link L-2-5
Randall 3020 P
42ENL
and 3060
PROGRAMMER
764321
Basic Boilers (see Page 27) L E N L N E
Barlo Balmoral 45F, 55F, 65F 9 6 10 11 12 L N E
Barlo Blenheim 30BF To 75BF LP 2 E N L L N E
Baxi Solo 30PF To 70PF PL SL E N L L N E
Glowworm Economy 24
7 SL E N L L N E
(remove link SL-9)
Glowworm Economy 30B To 50B 9 12 E 10 11 L N E
range (remove link 12-7)
Glowworm Fuelsaver MKII & F 9 12 E 10 11 L N E
range (remove link 12-7)
Glowworm Fuelsaver BR & R 7 SL E N L L N E
range (remove link SL-9)
Glowworm Spacesaver KFB50 9 12 E N L L N E
(remove link 12-7)
Glowworm Spacesaver 75
581325 46
(remove link 7-8)
Ideal Excell
Ideal Turbo 2 LP LB E N L L N E
Ideal Mexico Super 2
Myson Apollo
(remove all links)
PL ON E N L L N E
Myson Olympic (Use RED Plug)
(remove all links)
Myson Orion (After SEPT 88)
PL 4 E N L L N E
(remove all links)
Myson Economist Ro Ri E N L L N E
Potterton Flamingo (After June 89) PL SL E N L L N E
Potterton Netaheat 16-22 (Link 7-8) 6 7 E N L L N E
Potterton Netaheat Profile PL SL E N L L N E
For Vaillant VC/VCW and
Vokera 12-48 RSE contact office
for special wiring diagram
BOILER PUMP
9 8 3 2 1 9 8 2 3
240V
MAINS INPUT (3 AMP)
L1
N2
E3
240V
MAINS INPUT (13 AMP)
E
L
N
- 26 -
T6360B
ROOM
THERMOSTAT
14
35
22
OR
CM 41
CM 51
A
B
1
5
ELEMENT
3 KW 240V
~
Thermal
cut-out
Thermostat
L1
240V~
N
• 1
• 2
• 3
• 4
• 5
• 6
• 7
• 8
• 9
• 10
TYPICAL
JUNCTION BOX
1
P
Cylinder
thermostat
Thermal
cut-out
1
8
6
Not
used
P
2
1 P
2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ariston STD 100 DIRECT and is the answer not in the manual?

Ariston STD 100 DIRECT Specifications

General IconGeneral
BrandAriston
ModelSTD 100 DIRECT
CategoryWater Heater
LanguageEnglish

Related product manuals