the alarm in middle of the ceiling.
If the length of the room or the hall is beyond 10 meters, you need to install multiple
alarms.
In rooms with a combustion appliance place the detector at a horizontal distance between
1-3 meters from the CO source;
Avoid existing air inlets or outlets and other objects on the ceiling;
Avoid locations behind objects such as curtains and cupboards.
Don’t install on these locations
High-humidity areas such as kitchens and bathrooms.
Next to air outlets, fans and central heating.
Dusty, dirty areas or areas with insects.
High-temperature and easily polluted places.
Places with difficult access, making it difficult to operate the test function.
Within 1.5 meters from lamps.
Next to doors or windows.
In the top of rooms with sloping roofs, the corner of the room or other dead-air spaces.
Mounting the detector
Twist off the mounting bracket from the detector.
Put the bracket on the installation position and mark the 2 screw holes.
Drill two 5mm mounting holes and insert two plastic anchor plugs by hammer.
Screw the mounting bracket to the ceiling or the wall.
Attach the detector to the mounting bracket and turn clockwise to lock the device.
CAUTION
The installation instructions must be followed strictly to avoid unsafe conditions.
Do not paint your detector.
The battery cannot be replaced; do not try to replace the battery.