Manual Programming
The lock can be programmed manually using the keypad buttons 1 through 5. This feature is made avail-
able but programming using smart phone is highly recommended.
Manual Programming commands
A. To enter programming mode – press the #1 and the #5 buttons simultaneously
B. Enter the lock’s 6 digit master code (the master code will be on sticker on page 7 of user manual
and inside trim plate of lock)
C. The features below now accessible by entering a combination of two buttons one after the other
(not simultaneously)
1. To add a code enter # 1 and then # 3 then enter new code and enter again to
conrm (factory setting is 4 digit mode)
2. To delete a code enter # 4 and then # 3 then enter code to delete and enter again
to conrm
3. To change master
code
enter # 3 and then # 3
again
then enter new master code and enter again
to conrm
4. Deny Users ON enter # 4 and then # 1
5. Deny Users OFF enter # 5 and then # 1 (factory setting is OFF)
Deny Users can disable or enable all user codes – when ON, no user codes will work,
only key operates lock
6. Delete all codes enter # 5 and then # 5
again
7. Set 4 digit code length enter # 5 and then # 2 (factory setting is 4 digits)
8. Set 6 digit code length enter # 5 and then # 3
9. Beeper ON enter # 1 and then # 1
again
(factory setting is ON)
10. Beeper OFF enter # 1 and then # 2
11. Extended timeout
OFF
enter # 2 and then # 1 (factory setting is OFF)
12. Extended timeout
ON
enter # 2 and then # 2
again
Extended timeout mode allows for a longer duration of unlock time upon
entry of a valid user code.
13. Passage switch OFF enter # 3 and then # 1
14. Passage switch ON enter # 3 and then # 2 (factory setting is ON)
Passage switch mode ON, choose between Passage (lock unsecured) and Privacy (always locked) and
OFF lock is always in Privacy (always locked).
15. Restore factory
defaults
enter # 1 and then # 4 enter master code to conrm

Other manuals for Assa Abloy EMTEK LISCIO

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Assa Abloy EMTEK LISCIO and is the answer not in the manual?

Assa Abloy EMTEK LISCIO Specifications

General IconGeneral
BrandAssa Abloy
ModelEMTEK LISCIO
CategoryKeypad
LanguageEnglish

Related product manuals