1
HES 9400/9500/9600/9700
Electric Strike
Installation Instructions and Frame Preparation
Product Components
A 9400/9500/9600/9700 Strike Body
B 9400/9500/9600/9700 Cover
C 1/4"-20 x 1" Mounting Screws
D #10-32 & 10-24 Lockdown Screws (optional)
E #6-32 x 1/4" Cover Screws
F 5/64" Hex Key
G 12-Volt and 24-Volt Pigtails
UL1034
• Static Strength: 1500 lbs
• Dynamic Strength: 70 ft – lbs
• Endurance: 250,000 cycles
UL294 Performance Levels
• Destructive Attack: Level I
• Line Security: Level I
• Endurance: Level IV
• Standby Power: Level I
Electrical Specifications
Electrical Ratings for Solenoid
Continuous Duty 12 VDC 24 VDC
Resistance in Ohms 24 96
mA Continuous Duty 500 250
Solenoids are rated at +/- 10% indicated value.
Minimum Wire Gauge
Requirements
(Based on Round Trip)
Solenoid Voltage
12 VDC 24 VDC
200 feet or less 18 gauge 22 gauge
200 – 300 feet 16 gauge 22 gauge
300 – 400 feet 16 gauge 20 gauge
A
B
C
D
E
F
G
Diagram 1: Product Components
NOTE: Installation wiring for the product and
wiring methods shall be in accordance with the
National Electrical Code, ANSI/NFPA70