Instruction Book
34 6996 0223 70
4.2 Starting
Procedure
Check oil level and oil condition.
Switch on the voltage.
To avoid excessive energy consumption and damage to the pump, the maximum allowed
starting frequency is 30 starts per hour.
4.3 During operation
Regularly check the oil level and the oil condition. The oil level should be in the middle of the oil sight glass. Top up,
if necessary, with correct type of oil.
It is recommended to use genuine Atlas Copco Lubricants.
Filling the oil in gearbox
Follow below steps to fill the oil in gearbox:
Reference
Name
1
Oil filler plug
2
Oil sight glass
1 Remove the canopy panel(s) in order to get access to the internal components.
2 Remove the oil filler plug (1).
3 Pour oil in the gearbox up to the middle of the sight glass (2).
4 Close the filler plug. Remove all oil spills on the pump and/or floor.
5 Reinstall the canopy panel(s).