Step Action
1 Check that all bodywork panels are fitted.
Check that sheet (5) (explaining the procedure for checking the motor rotation direction)
is affixed to the cooling air outlet of the compressor (grating on the compressor top).
Consult Dimension drawings.
Switch on the voltage. Start the compressor and stop it immediately.
Check the rotation direction of the motor. If the motor rotation direction is correct, the label
on the top grating will be blown upwards. If the sheet remains in place, the rotation direction
is incorrect.
If the rotation direction is incorrect, switch off the voltage, open the isolating switch and
reverse two incoming electric lines.
All electrical work should be carried out by professionally qualified people.
2 Start and run the compressor for a few minutes. Check that the compressor operates
normally.
4.2 Starting
Air outlet valve
Condensate drain valve on air receiver
Instruction book
42 2920 7105 31