RRC13 EN Safety and operating instructions
© Atlas Copco Industrial Technique AB - 9836 978500 00
9
Maintenance
Lubrication
The tool should be lubricated with about 10 drops of oil once per shift. The oil
can be dropped either into the air hose or straight through the adapter (16).
When the tool is in continuous service, installation of an Atlas Copco oil-fog lu-
bricator in the compressed air line is recommended.
Use lubricants of good quality. The oils listed in the lubrication table are exam-
ples of lubricants that can be recommended.
Grease guide
Brand Grease Air lubrication
BP Energrease LS-EP2 Energol E46
Esso Beacon EP2 Arox EP46
Q8 Rembrandt EP2 Chopin 46
Mobil Mobilegrease XHP 222 Almo Oil 525
Shell Alvania EP2 Torcula 32
Texaco Multifak EP2 Aries 32
Molycote BR2 Plus
Overhaul
If the tool is used every day, it should be overhauled and cleaned once every six
months.
The filter in the adapter (16) should be cleaned frequently to prevent choking
with resultant decrease in capacity.
Useful information
Log in to Atlas Copco www.atlascopco.com
You can find information concerning our products, accessories, spare parts and
published matters on our website.
Ergonomic guidelines
Consider your workstation as you read through this list of general ergonomic
guidelines and see if you can identify areas for improvement in posture, compo-
nent placement, or work environment.
• Take frequent breaks and change work positions frequently.
• Adapt the workstation area to your needs and the work task.
• Adjust for convenient reach range by determining where parts or tools
should be located to avoid static load.
• Use workstation equipment such as tables and chairs appropriate for the
work task.
• Avoid work positions above shoulder level or with static holding during as-
sembly operations.