EasyManuals Logo
Home>Atmor>Water Heater>InLine 800 Series

Atmor InLine 800 Series User Manual

Atmor InLine 800 Series
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #6 background imageLoading...
Page #6 background image
5
07
1009
14
08
It is recommended that the appliance
electrical connections be tested once
a year by a qualied technician.
Aerator provided with 3kW models only
Assembly instructions
For optimal heating performance and proper
operation, the provided 0.5GPM aerator must
be installed to your sink faucet. This will ensure
a continuous ow and consistent, maximum
temperature rise. Output temperature will vary
depending on seasonality and inlet cold water
temperatures
Maximum of 0.5 GPM ow rate is needed for
optimal heating performance
Run the water ow for
one minute to check for
leakage before connecting
to power.
Reattach the front cover
of the heater and secure
it with 4 screws and then
slide the bottom gray cover
Connect the power cable to the
terminal block.
Caution: The heater must be
grounded.
Reference gure *3 on page 4 and
Electrical diagram on page 6
When installed outdoors,
the heater must be
placed in sealed
waterproof electrical box.
Make sure that the
appliance is lled with
water before connecting
power. (Repeat step 7)
12
11
13
Do not install the heater
where it may be subject to
direct sunlight.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atmor InLine 800 Series and is the answer not in the manual?

Atmor InLine 800 Series Specifications

General IconGeneral
BrandAtmor
ModelInLine 800 Series
CategoryWater Heater
LanguageEnglish

Related product manuals