TCD210185AC
Display Type
Pressure Sensors
PSAN Series
PRODUCT MANUAL
For your safety, read and follow the considerations written in the instruction
manual, other manuals and Autonics website.
The specications, dimensions, etc are subject to change without notice for product
improvement Some models may be discontinued without notice.
ᜢ ᜫ
Features
• Pressure measurement of any gas, liquid or oil (except substances which may corrode
stainless steel 304/316L)
• Auto shift function: with change in the original pressure, the external input adjusts the
determined level to match the change in pressure (only available in models with auto
shift/hold function)
• Hold function: hold current display value or control output
• Forced output control mode for device testing and maintenance
• One-touch connector type for easy wiring and maintenance
• Zero-point adjustment function, peak value monitoring function, chattering
prevention function
Safety Considerations
• Observe all ‘Safety Considerations’ for safe and proper operation to avoid hazards.
• symbol indicates caution due to special circumstances in which hazards may occur.
Failure to follow instructions may result in serious injury or death.
01.
Failure to follow this instruction may result in personal injury, economic loss or re.
02.
Failure to follow this instruction may result in explosion or re.
03.
Failure to follow this instruction may result in re.
04.
source.
Failure to follow this instruction may result in re.
05.
Failure to follow this instruction may result in re.
06. Do not disassemble or modify the unit.
Failure to follow this instruction may result in re or electric shock.
Failure to follow instructions may result in injury or product damage.
01.
Failure to follow this instruction may result in re or product damage.
02.
Failure to follow this instruction may result in re.
03.
not use for corrosive medium.
Failure to follow this instruction may result in product damage.
04.
into the unit.
Failure to follow this instruction may result in re or product damage.
• Follow instructions in ‘Cautions during Use’.
Otherwise, it may cause unexpected accidents.
• 12 - 24 VDCᜡ power supply should be insulated and limited voltage/current or Class 2,
SELV power supply device.
• Use the product, 3 sec after supplying power.
• When using switching mode power supply, frame ground (F.G.) terminal of power
supply should be grounded.
• Wire as short as possible and keep away from high voltage lines or power lines, to
prevent inductive noise.
• This unit may be used in the following environments.
- Indoors (in the environment condition rated in ‘Specications’)
- Altitude max 2,000 m
- Pollution degree 3
- Installation category II