22
Fig. 15
retaining screws
Fig. 28 - Dismantling gas valve
Fig. 29 - Dismantling fan
Qualied personnel should inspect the appliance
following the law in force, this is to ensure correct,
continuous and reliable operation of the water heater.
Insu󰀩cient or inadequate maintenance can compro-
mise the safety of the appliance.
Before carrying out any cleaning or maintenance, switch
o󰀨 the appliance using the omni-polar switch on the power
supply line and close the gas and water valves to the appli-
ance.
External cleaning
A periodic cleaning of the external panels as well as improving
the appearance, it preserves the corrosion paneling, extending
its life.
To clean the exterior panels use a cloth dampened with soapy
water.
Do not use solvents, powders or abrasive sponges.
Do not clean the appliance and/or its parts with ammable sub-
stances (example: petrol, alcohol, oil, etc.).
Dismantling the casing (Fig. 26)
Remove the casing by unscrewing the fastening screws located
on the bottom of the water heater and detaching the casing at
the top.
Accessibility to the electronic board (Fig. 27)
Remove the casing by referring to the specic paragraph.
Remove the panel by unscrewing the screws that secure it to
the seat of the electronic board.
Disconnect the connectors.
Removing the gas valve (Fig. 28)
Remove the casing by referring to the specic paragraph.
Unscrew the screws that secure the panel to the bottom shelf.
Remove the panel without disconnecting the wiring and attach
it to the bracket as shown in the gure.
Disconnect the gas valve by unscrewing the retaining screws
and the nut connecting to the gas pipe.
Removing the fan (Fig. 29)
Remove the casing by referring to the specic paragraph.
Unscrew the xing screws of the fan.
Lower the fan freeing it from the hooks and slide it to the left.
Removing the burner (Fig. 30a-30b-30c-30d)
Remove the casing by referring to the specic paragraph.
Remove the clip (detail A g. 30a).
Disconnect and remove the cold water pipe and the two gas
pipe (g. 30a).
Turn the screws showed in g. 30a and lower the plate.
Referring to g. 30b: unscrew the nut, remove the clip and ex-
tract the hot water outlet pipe.
Turn the xing screws in g. 30c and remove the burner.
MAINTENANCE
Fig. 27 - Accessibility to the electronic board
Fig. 26 - Dismantling the casing
Fig. 17 b
Fig. 30a - Dismantling burner
Fig. 15
A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Baxi 14Fi AM Blue and is the answer not in the manual?

Baxi 14Fi AM Blue Specifications

General IconGeneral
BrandBaxi
Model14Fi AM Blue
CategoryGas Heater
LanguageEnglish

Related product manuals