Installation Instructions
Power Supply Connection
The 5-pin CAGE CLAMP plug connector and mounting flange illustrated is
located on the PC housing in order to connect the power supply.
Socket at the PC housing
Technical data Connecting socket
Number of contacts
5
Contact spacing
5 mm
Minimum conductor cross-section
1.5 mm²
Minimum conductor cross-section
(AWG)
16
Rated voltage (EN)
250 V
Rated voltage (CSA)
300 V
Current EN [A]
12 A
Current CSA [A]
15 A
Length of stripped conductor
8 to 9 mm
Supplied mains power unit
The Industrial PCs is either fitted with a 100-240 V, 50-60 Hz power supply
unit (standard) or with a 24 V
DC
power supply unit (with the option of an
uninterruptible power supply, UPS).
Current carrying capacity of the 100-240 V power supply
unit
C6110, C6120, C6130
Output voltages from
the 100-240 V power
supply unit
Current loading
maximum
+3.3 V 14 A
+5 V stand by
1.5 A
+5 V
16 A
-5 V
0.2 A
+12 V
9 A
-12 V
0.7 A
C6140, C6150
Output voltages from
the 100-240 V power
supply unit
Current loading
maximum
+3.3 V
16 A
+5 V stand by
2 A
+5 V
25 A
-5 V
0.3 A
+12 V
13 A
-12 V
0.8 A
C61xx 11