The CP.BULL and MATRIX-RE control units are equipped with connector for extractable receiver.
To access programming:
1 Press the button <PG>, the display goes to the first menu, Parameters “PAR”.
2 With the <+> or <-> button, select the menu you want (PAR>>LOG>>RADIO>>NMAN>>RES)
3 Press the button <PG>, the display shows the first function available on the menu.
4 With the <+> or <-> button, select the function you want.
5 Press the button <PG>, the display shows the value currently set for the function selected.
6 With the <+> or <-> button, select the value you intend to assign to the function.
7 Press the button <PG>, the display shows the signal “PRG” which indicates that programming has been completed.
Notes:
Simultaneously pressing <+> and <-> from inside a function menu allows you to return to the previous menu without making any
changes.
Simultaneously pressing <+> and <-> when the display is switched off shows the card software release.
Hold down the <+> key or the <-> key to accelerate the increase/decrease of the values.
After waiting 30s the control unit quits programming mode and switches off the display.
Parameters, Logic and Special Functions
The tables below describe the individual functions available in the control unit.
MENU FUNCTION
Settable values
MIN-MAX-(Default)
MEMO
PARAMETERS
TCA
Automatic closure time. It is activated only with “TCA”=ON logic.
At the end of the preset time, the control unit controls a closure operation.
1-240-(40s)
Tped
The passage left open by the gate leaf during the partial opening (pedestrian)
is adjusted.This value is expressed in decimetres.
2-100-(5dm)
Tsm
The area covered by the gate during the braking phase is adjusted.
0 = braking disabled. The performance of the automatic system during the first
operations depends on the ENC logic.
See section “Operating mode with enabled/disabled Encoder”.
0-100-(0%)
PMo
The torque applied to the motor in the opening phase is adjusted.*
1-99-(50%)
PMC
The torque applied to the motor in the closing phase is adjusted *. 1-99-(50%)
Pso
The torque applied to the motor during braking in the closing phase is adjusted.*
1-99-(50%)
Psc
The torque applied to the motor during braking in the opening phase is adjusted *
1-99-(50%)
SeaU
The intervention threshold of the anti-crashing device (Encoder) during the
phase at normal speed is adjusted.*
0:Off-1:maximum sensitivity - 99: minimum sensitivity
0-99-(0%)
SEAR
The intervention threshold of the anti-crashing device (Encoder) during braking
is adjusted *.
0:Off-1:maximum sensitivity - 99: minimum sensitivity
0-99-(0%)
TLS
Activated only with SERL:ON Logic. The activation time of the service light is
adjusted.
1-240-(60s)
Ibra
The force of the motor brake is adjusted.
0: disabled braking - 1:minimum braking - 99: maximum braking
0-99-(50%)
TM
It is activated only with SERL logics EN : OFF.
Operating time. The operating time is adjusted at normal speed
during motor opening and closing phases.
1-250-(90s)
BLC
Motor stop delay on limit switch. It is activated only with enabled braking
(TSM).
The motor stop delay is adjusted after the triggering of the limit switch. Use a
value calibrated on the gate weight. Use these indicative values:
0 deactivated (no delay)
1 very heavy gates (short delay)
2 heavy gates
3 average gates
4 light gates (longer delay)
0-4 (0)
* WARNING:
An incorrect setting of these parameters may result in a danger. Comply with regulations in force!