9. External dimensions
10. Specifications
0 to 230 V (secondary side of transformer)
Function to control operation by external
signals
Synchronization
signal output
Output in synchronization with vibrator
operation (2 points)
Workpiece
shortage signal
Workpiece shortage signal output from full
sensor*1
Startup delay setting at a stop due to full*1
Delay setting for stop due to full at operation
state*1
Constant amplitude
function
Constant amplitude control by acceleration
sensor (PHA-03)*1
Ambient operating temperature
0 to 40°C (freezing not allowed)
Ambient operating humidity
0 to 90% RH (condensation not allowed)
*1 AFC-20HG function
11. Initialization
Data is erased completely and all settings return to initial values if the power supply is
turned ON while pressing the “RUN/STOP” key.
Be sure to prepare needed data in advance.
12. Troubleshooting
A. Indicators and lamps
do not turn ON when
the power supply is
turned ON.
Is the power cable connected
correctly?
B. Vibration does not
occur (The Run lamp
is ON).
Is the output line connected
correctly?
C. Vibration does not
occur (The Run lamp
is OFF.)
Press the RUN/STOP button to
switch to the operation state.
D. Vibration does not
occur (The Run lamp
is blinking)
Check the external operation signal
and the full sensor as well as their
parameters.
E. The amplitude is not
increased when
voltage is increased.
Is the frequency adjusted properly?
Isn’t the used load outside the
specified range?
Instruction
manual for the
vibrator
F. The output frequency
cannot be adjusted.
G. The vibration
fluctuates.
Is the frequency adjusted properly?
Is the load attached firmly?
Is it free from interference with
peripheral devices?
Instruction
manual for the
vibrator
H. Abnormal noise from
the controller
Stop using the controller immediately
and turn OFF the power supply.
Contact the dealer.
I. Abnormal smell from
the controller
13. Warranty
1. The warranty period is one year after delivery of the product.
(Operation time per day is counted as 8 hours.)
2. The warranty does not cover the following cases:
a. Failures attributable to disassembly or modification by the
customer
b. Failures that are obviously attributable to erroneous use
c. Failures caused by natural disasters such as fire, earthquake
and flood
d. Failures caused by non-conformity to use conditions, use
methods and precautions written in the instruction manual
3. As for repair for a fee, the fee will be charged upon discussion.
BM172010
Sales Division, BFC Limited
Head office TEL: 0567-56-2550 FAX: 0567-56-2552
Postal code 490-1435, Nishiume 103-1,
Umenogo, Tobishima-mura, Ama-gun, Aichi
Prefecture
Osaka Sales Office TEL: 06-4806-4777 FAX: 06-4806-4778
Postal code 532-0011, Hanahara Daini
Building 702, Nishi-Nakajima 4-11-27,
Yodogawa-ku, Osaka City
BFC Applications, Ltd.
Tokyo Sales Office TEL: 03-5905-7160 FAX: 03-5905-7161
Postal code 178-0063, MB 1F, Higashi-Oizumi
3-42-8, Nerima-ku, Tokyo