Tab.33
TC52 TC5310
TC76T
TC5410
Approachdirection ±X,±Y,‐Z ±X,±Y, ±Z
a
a
seechapter4.5
±X,±Y, ±Z
a
Measuringforce
•directionX/Y: seeTab.35...Tab.37
Measuringforce
•directionZ: 5,7 N
1.6 N
10 N(TC52T)
5,9 N
2.0 N
5,9 N
2.0 N
10.6 N
(TC5410)
Max.deflection
•directionX/Y(seeTab.34):
± 11°
±9°(TC52T) 15° ± 15°
•directionZ: 6mm
3.5 mm(TC52T)
5mm 5mm
Max.acceleration 50 m/s
2
200 m/s
2
(TC52T)
50 m/s
2b
b
withaccessories(e.g.extension,angle):max.acceleration10m/s
2
50 m/s
2
200 m/s
2
(TC5410T)
Repeatability
c
c
StylusL=30mm
0.3 µm 2σ
(Standard)
Z:0.2 µm 2σ(LF)
XY:0.3 µm 2σ(LF)
0.4 µm 2σ 0.4 µm 2σ
Max.probingspeed 2 m/min 2 m/min 2 m/min
Mass 250 g 225 g
(TC5310)
230 g
Protectionclass IP68
Signaltransmission Infrare d
Transmitterrange ±60°inZ,360°inX/Y
Battery(2pieces) SaftLithiumLS14250 AA, 3.6 V) 1200 mAh
ToolholderHSKSKBT BTH25
Storagetemperature 20 °C ... +70 °C
Oper atingtemperature +C...+5C