Systemoverview
©byBlum‐Novotest
11
V2A|04/2018
Tab.3‐4Max.deflectionX/Y
Tab.3‐5MeasuringforceX/Y
Tab.3‐6MeasuringforceX/Y‐T(robustdesignforlathesapplications)
Max.deflectionX/Y[mm]
Styluslength[mm] TC50 TC51 TC52
TC52LF
TC52T TC53‐10/TC76
TC53‐30/TC76
TC54‐10
TC54‐10T
30 14 14 7 6 12
50 19 19 11 9 17
75 26 26 16 13 24
100 32 32 20 17 30
150 44 45
200 57 58
MeasuringforceX/Y[N]
Styluslength[mm] TC50 TC51 TC52 TC53‐10/TC76
TC53‐30/TC76
TC54‐10
30 2.0 1.5 2.3 1.3
50 2.0 1.5 1.5 0.9
75 2.0 1.5 1.1 0.7
100 1.4 1.2 0.8 0.5
150 1.0 0.9
200 0.8 0.7
MeasuringforceX/Y‐T[N]
Styluslength[mm] TC52T TC53‐10/TC76‐TT
TC53‐30/TC76‐TT
TC54‐10T
30 4.1 2.3
50 2.7 1.6
75 1.9 1.15
100 1.5 0.9