1. Close all doors.
2. Slide the switch forwards beyond the resist‐
ance point and hold it in this position.
The Glass Roof is closed with limited anti-
trap function. If the closing force exceeds a
certain level, the closing operation is interrup‐
ted.
3. Press the switch forwards once again beyond
the resistance point and hold until the Glass
Roof closes with no anti-trap function. Ensure
that the closing area is clear.
Closing without the anti-trap
mechanism from a raised position
In the event of danger, proceed as follows:
1.
Close all doors.
2. Slide the switch forwards beyond the resist‐
ance point and hold it in this position.
The Glass Roof is closed with no anti-trap func‐
tion.
Initialising after a power failure
General
If a power failure occurs while the Glass Roof is
opening or closing, it may only have limited func‐
tionality afterwards.
The system can be initialised under the following
conditions.
▷ The vehicle is parked on level ground.
▷ In drive-ready state.
▷ The outside temperature is above 5 ℃/41 ℉.
During initialisation, the Glass Roof closes with
no antitrap mechanism.
Ensure that the closing area is clear.
Initialising the system
Press the switch up and hold until
initialisation is complete:
Initialisation begins within 15 seconds.
▷ If the Glass Roof is closed, it opens, then
closes again.
▷ If the Glass Roof is open, it first closes, then
opens and closes again.
Initialisation is complete once the Glass Roof and
sun guard have opened then closed again.