Page 93
-
•
• --
• -
•
•
Key Value Descripon
$0 5 (Step pulse me, microseconds)
$1 25 (Step idle delay, milliseconds)
$2 0 (Step pulse invert, mask)
$3 0 (Step direcon invert, mask)
$4 0 (Invert step enable pin, boolean)
$5 1 (Invert limit pins, boolean)
$6 0 (Invert probe pin, boolean)
$10 1 (Status report opons, mask)
$11 0.01 (Juncon deviaon, millimeters)
$12 0.002 (Arc tolerance, millimeters)
$13 1 (Report in inches, boolean)
$20 1 (So limits enable, boolean)
$21 0 (Hard limits enable, boolean)
$22 1 (Homing cycle enable, boolean)
$23 3 (Homing direcon invert, mask)
$24 500 (Homing locate feed rate, mm/min)
$25 8000 (Homing search seek rate, mm/min)
$26 250 (Homing switch debounce delay, milliseconds)
$27 5 (Homing switch pull-o distance, millimeters)
$30 1000 (Maximum spindle speed, RPM)
$31 0 (Minimum spindle speed, RPM)
$32 0 (Laser-mode enable, boolean)
$100 80 (X axis travel resoluon, step/mm)
$101 80 (Y axis travel resoluon, step/mm)
$102 2267.717 (Z axis travel resoluon, step/mm)
$110 10000 (X axis maximum rate, mm/min)
$111 10000 (Y axis maximum rate, mm/min)
$112 500 (Z axis maximum rate, mm/min)
$120 800 (X axis acceleraon, mm/sec^2)
$121 800 (Y axis acceleraon, mm/sec^2)
$122 300 (Z axis acceleraon, mm/sec^2)
$130 610 (X axis maximum travel, millimeters)
$131 610 (Y axis maximum travel, millimeters)
$132 85 (Z axis maximum travel, millimeters)