EasyManuals Logo
Home>Bosch>Control Panel>2000 Series

Bosch 2000 Series User Manual

Bosch 2000 Series
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #54 background imageLoading...
Page #54 background image
2000 Series | Program Entry Guide | 13.0 Relays EN | 54
Bosch Security Systems | 7/05 | 35114F
Table 18: Relay Function Selections
Programmers Keypad Description
No Output 0
No output at the relay terminal.
Alarm 1
Provides a steady output when a point is in an alarm condition.
The relay output follows Bell Time.
Note:
This output does not occur for alarms caused by A, B, C Keys.
Entering a combination to acknowledge an alarm resets the relay.
Select the points to monitor for alarms at the Parameter prompt.
Alarm Memory 2
Provides a steady output when a point shows alarm memory at the keypad.
Turning the system on clears alarm memory and ends the output. This output
does not occur for alarms caused by A, B, C Keys.
Select the points to monitor for alarm memory at the Parameter prompt.
Point Trouble 3
Provides a steady output when selected points are in trouble.
Select the points to monitor for troubles at the Parameter prompt. Swinger
bypass is a point trouble and activates the Point Trouble Relay function.
Follow Point 4
Provides a steady output when selected points are faulted (including point trouble
and alarm).
Select the points to monitor for faults at the Parameter prompt.
Watch Tone 5
Activates the relay output in parallel to the watch tone for selected points. Refer to
Key 7, Watch Tone in the User’s Guide. If you set the watch tone to No Tone, the
Watch Tone relay does not activate. Select the points for Watch Tone monitor at
the Parameter prompt.
A,B,C Key, Steady 6
Activates the relay output when a user presses a selected function key. The relay
output remains activated until a user performs a System Reset (presses [3] and
enters a passcode).
Select the function keys to monitor at the Parameter prompt.
A,B,C Key, Pulse 7
Activates the relay output when a user presses a selected function key. The relay
output pulses until a user performs a System Reset (presses [3] and enters a
passcode).
Select the function keys to monitor at the Parameter prompt.