4.5 KBR..-3A appliances with DHW tank:
Setting
the DHW temperature
DANGER
Risk of scalding!
▶ in normal operation, it is recommended to limit the DHW temperature to 122 °F
(50 °C) to limit the risk of scalding.
▶ Only set temperature up to 158 °F (70 °C) for thermal disinfection page 26.
▶ Set the DHW temperature on the DHW thermostat *. The se
t DHW temperature
flashes on the display for 30 seconds.
6 720 641 933-54.1O
max
1
2
34
5
6
reset
eco
max
1
2
3
4
e
6
if there is reason for concern for contamination from bacteria such as Legionella,
consider setting the DHW thermostat * to at least “e” (131 °F (55 °C)). This setting
ensur
es an economical and comfortable DHW generation. Consult your local water
department or municipality for further information.
DHW thermostat * Typical DHW temperatures
min approx. 59 °F (15
°C)
e approx. 131 °F (55 °C)
max approx. 158 °F (70 °C)
Table 4