Bosch Power Tools 2 609 140 996 | (23.9.13)
Signal LED 2 flashes red over a large measuring area on the wall
(warning of “live” cables)
Improper grounding
of the wall
With your free hand, touch the wall at a distance of
20 30 cm from the measuring tool to ground the
wall.
“Live” cable is not found
No/atypical voltage
on the cable
Add voltage to the cable, for example by turning on
light switches assigned to it. The detection of ca-
bles with AC voltages outside of the range
110 240 V, 50 60 Hz is not reliably possible.*
Cable is located too
deep
The scanning depth is dependent on the building
material and may be less than the maximum scan-
ning depth.*
Cable runs in
grounded metal pipe
Use the measuring tool to locate the metal pipe.
Measuring tool is not
grounded
Hold the measuring tool firmly without gloves. Do
not stand on insulating ladders or scaffolding. Do
not wear insulating footwear.
Screened-off build-
ing material or high
air humidity
A reliable detection is not possible with metallic or
moist building materials (e.g. at high air humidity).*
Metal object is not located
Metal object is locat-
ed too deep
The scanning depth is dependent on the building
material and may be less than the maximum scan-
ning depth.*
Metal object is too
small
The scanning depth is dependent on the building
material and may be less than the maximum scan-
ning depth.*
Uncoordinated flashing in colours green, yellow, red
Interference caused
by electric or mag-
netic fields
Keep your distance from devices emitting strong
electric or magnetic fields (e.g. computers, switch
mode power supplies).
Cause Corrective Measure
OBJ_BUCH-1913-002.book Page 23 Monday, September 23, 2013 12:33 PM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch PMD 7 and is the answer not in the manual?

Bosch PMD 7 Specifications

General IconGeneral
Display type-
Product colorBlack, Green
Auto calibrationYes
Built-in displayNo
Detectable materialsLive cable, Non-ferrous metal
Maximum detection depth (steel)70 mm
Maximum detection depth (copper)60 mm
Maximum detection depth (live cable)50 mm
Battery life5 h
Battery typeAAA
Battery voltage1.5 V
Battery technologyAlkaline
Auto power off after10 min
Number of batteries supported3
Storage temperature (T-T)-20 - 70 °C
Operating temperature (T-T)0 - 40 °C
Weight and Dimensions IconWeight and Dimensions
Weight150 g