Troubleshooting
Tronic 3000T – 6 720 892 061 2019/02
14
7.1 Resetting High Limit Switch
Occasionally, the high temperature limit shut off device may
trip the reset. This occurs when water temperature exceeds
190 °F. The shut off device may also trigger from a power
outage or electrical storm.
To reach the thermostat:
Disconnect power cord (or shut off circuit breaker - model
ES8) and remove the front cover.
Firmly press reset button [B] with the tip of a ball point pen
or similar object.
Fig. 12
A click indicates the reset was tripped.
Reconnect power.
IMPORTANT: Check the operation of the thermostat:
Turn temperature dial from high to low.
If the red light does not go off on low setting:
Turn off power supply and call a service person to replace
the thermostat.
If the red light does go off the thermostat is working well:
Place dial setting to desired setting.
A lower setting is more economical and reduces the risk of
scalding.
Replace cover plate.
CAUTION:
Call a technician if the high limit needs to be reset frequently.
6720801072-12.1V

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch Tronic 3000T ES2.5 and is the answer not in the manual?

Bosch Tronic 3000T ES2.5 Specifications

General IconGeneral
Capacity2.5 gallons
Voltage120V
Installation TypeWall-mounted
Water Connection1/2 inch NPT
Max. operating pressure150 psi
Amperage12 amps
PhaseSingle-phase
Wattage1440W

Related product manuals