Technical data
11
Tronic 4000 | 5000 | 6000 | 7000 – 6720876037 (2021/08)
actuation has been found / eliminated, the SL can be switched on
again by pressing the lock down button. Water pressure peaks in
installation due to flushing systems, pumping systems could trigger
the SL, so pressure regulation valves are advised at supply line in
order to minimize possible perturbations.
3Technical data
TR4000
18 EB
TR4000
21 EB
TR4000
24 EB
TR4000
27 EB
Rated output [kW] 18 21 24 27
Rated voltage [V] 400 400 400 400
Fuse protection [A] 32 32 40 40
Minimum conductor cross-section* [mm
2
] 4 4 6 6
Warm water flow at rated output
with temperature increase from
12 °C to 38 °C (without flow-rate limiter)
12 °C to 38 °C (with flow-rate limiter)
12 °C to 60 °C
[l/min]
[l/min]
[l/min]
9.8
6.5
5.3
11.6
7.6
6.2
13
8.7
7.1
14.6
9.3
7.9
Start-up flow [l/min] 2.5 2.5 2.5 2.5
Start-up flow pressure** [MPa (bar)]
0.04
0.4
0.04
0.4
0.04
0.4
0.04
0.4
Application area in water
specific electric resistance at 15 °C
[Ωcm] ≥ 1 300 ≥ 1 300 ≥ 1 300 ≥ 1 300
Rated pressure [MPa (bar)] 1.0 (10) 1.0 (10) 1.0 (10) 1.0 (10)
Maximum permissible supply temperature [°C] 20 20 20 20
Maximum mains impedance at connection point [Ω] 0.104 0.104 0.104 0.104
Energy efficiency class A A A A
Load profile SSSS
Annual energy consumption [kWh] 479 477 477 479
Daily energy consumption [kWh] 2,204 2,195 2,191 2,204
Sound power level [dB] 15 15 15 15
Hot water heating energy efficiency [%] 39393939
TR5000
11/13 EB
TR5000
15/18 EB
TR5000R
18/21 EB
TR5000
21/24 EB
TR5000
24/27 EB
TR5000R
24/27 EB
Rated output [kW] 11/13 15/18 18/21 21/24 24/27
Rated voltage [V] 400 400 400 400 400
Fuse protection [A] 25 32 32 40 40
Minimum conductor cross-section* [mm
2
] 2.5 4 4 6 6
Warm water flow at rated output
with temperature increase from
12 °C to 38 °C (without flow-rate limiter)
12 °C to 38 °C (with flow-rate limiter)
12 °C to 60 °C
[l/min]
[l/min]
[l/min]
6.0/7.1
5
3.3/3.8
8.1/9.8
6.5
4.4/5.3
9.8/11.6
7.6
5.3/6.2
11.6/13.0
8.7
6.2/7.1
13.0/14.6
9.3
7.1/7.9
Start-up flow [l/min] 2.5 2.5 2.5 2.5 2.5
Start-up flow pressure** [MPa (bar)]
0.04
0.4
0.04
0.4
0.04
0.4
0.04
0.4
0.04
0.4
Application area in water
specific electric resistance at 15 °C [Ωcm] ≥ 1 300 ≥ 1 300 ≥ 1 300 ≥ 1 300 ≥ 1 300
Rated pressure [MPa (bar)] 1.0 (10) 1.0 (10) 1.0 (10) 1.0 (10) 1.0 (10)
Maximum permissible supply temperature [°C] 20 20 20 20 20
Maximum mains impedance at connection point [Ω] 0.433 0.067/0.104 0.067/0.104 0.067/0.104 0.067/0.104
Energy efficiency class A A A A A
Load profile XSSSSS
Annual energy consumption [kWh] 471 479 477 477 479
Daily energy consumption [kWh] 2,160 2,204 2,195 2,191 2,204
Sound power level [dB] 15 15 15 15 15
Hot water heating energy efficiency [%]3939393939