HEAT PUMP HEATING PERFORMANCE -- CONTINUED
INDOOR AIR
OUTDOOR COIL ENTERING AIR TEMPERATURES deg F
--- 3 7 17 27 37 47 57 67
EDB CFM
Capacity
MBtuh
Tot a l
Sys-
tem
KW†
Capacity
MBtuh
Tot a l
Sys-
tem
KW†
Capacity
MBtuh
Tot a l
Sys-
tem
KW†
Capacity
MBtuh
Tot a l
Sys-
tem
KW†
Capacity
MBtuh
Tot a l
Sys-
tem
KW†
Capacity
MBtuh
Tot a l
Sys-
tem
KW†
Capacity
MBtuh
Tot a l
Sys-
tem
KW†
Capacity
MBtuh
Tot a l
Sys-
tem
KW†
Tot a l
In-
teg*
Tot a l
In-
teg*
Tot a l
In-
teg*
Tot a l
In-
teg*
Tot a l
In-
teg*
Tot a l
In-
teg*
Tot a l
In-
teg*
Tot a l
In-
teg*
25HBR360A Outdoor Section With FC4DNF060 Indoor Section
65
1750 25.42 23.39 3.96 30.92 28.42 4.10 36.95 33.69 4.27 43.61 38.73 4.45 51.09 46.49 4.67 59.02 59.02 4.84 66.24 66.24 5.05 65.65 65.65 5.01
2000 25.81 23.75 4.00 31.33 28.79 4.14 37.39 34.09 4.29 44.11 39.18 4.46 51.73 47.08 4.63 58.54 58.54 4.78 61.87 61.87 4.86 59.50 59.50 4.78
2250 26.18 24.08 4.06 31.71 29.14 4.18 37.79 34.46 4.33 44.55 39.57 4.48 51.85 47.18 4.61 57.18 57.18 4.74 58.08 58.08 4.75 55.04 55.04 4.67
70
1750 24.91 22.92 4.11 30.49 28.02 4.28 36.53 33.30 4.46 43.11 38.29 4.65 50.48 45.93 4.87 58.78 58.78 5.06 66.16 66.16 5.29 67.06 67.06 5.30
2000 25.31 23.28 4.16 30.90 28.39 4.31 36.97 33.71 4.47 43.61 38.73 4.65 51.10 46.50 4.86 58.50 58.50 5.00 63.00 63.00 5.12 61.80 61.80 5.07
2250 25.67 23.62 4.22 31.26 28.73 4.35 37.37 34.07 4.51 44.05 39.12 4.67 51.64 46.99 4.83 58.08 58.08 4.98 60.16 60.16 5.02 57.77 57.77 4.95
75
1750 24.36 22.41 4.27 30.00 27.57 4.45 36.07 32.89 4.64 42.61 37.85 4.85 49.92 45.43 5.08 58.19 58.19 5.31 66.02 66.02 5.54 68.87 68.87 5.63
2000 24.76 22.78 4.32 30.42 27.96 4.49 36.52 33.30 4.66 43.09 38.27 4.85 50.48 45.93 5.06 58.37 58.37 5.23 64.89 64.89 5.42 64.86 64.86 5.40
2250 25.13 23.12 4.38 30.81 28.31 4.53 36.93 33.67 4.69 43.54 38.67 4.87 51.04 46.44 5.06 58.07 58.07 5.20 61.75 61.75 5.29 60.03 60.03 5.24
Heating Indoor Model Capacity Power Furnace Model
*FC4DN(F,B)060 1.00 1.00
FK4DNB006 1.02 1.06
CAR**6024A** 1.00 1.03 58CV(A,X)135---22
CSRH*6012A** 1.01 1.02 58CV(A,X)135 ---22
CAR**6024A** 1.00 1.02 58CV(A,X)155---22
CNRH*6024A** 1.01 1.04 58CV(A,X)155---22
CNRV*6024A** 1.01 1.04 58CV(A,X)155 ---22
CSRH*6012A** 1.01 1.01 58CV(A,X)155 ---22
NOTE: When the required data falls between the published data, interpolation may be performed. Extrapolation is not an acceptable practice.
* The Btuh heating capacity values shown are net integrated values from which the defrost effect has been subtracted. The Btuh heating from supplement
heaters should be added to those values to obtain total system capacity.
{ The kW values include the compressor, outdoor fan motor, and indoor blower motor. The kW from supplement heaters should be added to these values to
obtain total system kilowatts.
EDB Entering Dry Bulb
25HBR3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Carrier 25HBR3 and is the answer not in the manual?

Carrier 25HBR3 Specifications

Electrical Requirements IconElectrical Requirements
nominal unit electrical characteristics (single phase)v, single phase, 60 hz
nominal unit electrical characteristics (three phase)v, three phase, 60 hz
control circuit voltage24v
Fan Specifications IconFan Specifications
condenser fan typedirect-drive propeller type
condenser fan motor typetotally enclosed, 1-phase type
fan blade balancestatically and dynamically balanced