7
LEGEND
*Air-Conditioning & Refrigeration Institute.
†Applies only to units with capacity of 65,000 Btuh or less.
**The IPLV is not applicable to single-compressor units.
NOTES:
1. Rated in accordance with ARI Standard 210/240 (004-012 units) or 360 (014 units) and 270 (004-014 units).
2. Ratings are net values, reflecting the effects of circulating fan heat. Ratings are based on:
Cooling Standard:
80 F db, 67 wb indoor entering-air temperature and 95 F db outdoor entering-air temperature.
IPLV Standard:
80 F db, 67 F wb indoor entering-air temperature and 80 F db outdoor entering-air temperature.
HEATING CAPACITIES AND EFFICIENCIES
LEGEND
*Single-phase units are rated for output capacity in accordance with
U.S. Government Standard Tests.
†Three-phase units are rated for output capacity in accordance with
ANSI Z21.47 Standard for gas-fired, central furnaces.
NOTE: NOx levels are 40 nanograms/
joule with accessory kit.
UNIT
48HJ
NOMINAL
TONS
STANDARD
CFM
COOLING
(Btuh)
TOTAL
kW
SEER† EER
SOUND RATING
(Bels)
IPLV
E/F004
3 1200 36,000 3.21 13.0 11.20 7.6 **
D/E/F005
4 1450 47,000 4.25 13.0 11.05 7.6 **
D/E/F006
5 1750 61,000 5.55 13.0 11.00 8.0 **
D/E/F007
6 2100 74,000 6.70 — 11.00 8.0 **
D/E/F008
7.5 3000 90,000 8.18 — 11.00 8.2 11.6
D/E/F009
8.5 3000 102,000 9.44 — 10.80 8.2 10.9
D/E/F012
10 3200 120,000 10.91 — 11.00 8.4 9.7
D014
12.5 4300 139,000 14.04 — 9.5 8.6 9.8
E014
12.5 4300 139,000 14.04 — 9.5 8.6 9.4
Bels —
Sound Levels (1 bel = 10 decibels)
EER —
Energy Efficiency Ratio
IPLV —
Integrated Part-Load Value
SEER —
Seasonal Energy Efficiency Ratio
UNIT
HEATING INPUT
(Btuh)
First Stage/Second Stage
OUTPUT CAPACITY (Btuh)
TEMPERATURE
RISE (
°
F)
AFUE
(%)
STEADY STATE
EFFICIENCY (%)
CALIFORNIA
SEASONAL
EFFICIENCY (%)
Single-Phase Units*
First Stage/Second Stage
3-Phase Units†
First Stage/Second Stage
48HJE004
50,000/ 72,000 40,000/ 57,100 41,000/ 59,040 15-45 82 82 78.7
48HJF004
82,000/115,000 63,500/ 89,000 65,600/ 92,000 55-85 80 80 77.3
48HJD005
50,000/ 72,000 40,000/ 57,100 41,000/ 59,040 15-45 82 82 78.7
48HJE005
82,000/115,000 65,600/ 92,000 66,420/ 93,150 35-65 81 81 77.7
48HJF005
120,000/150,000 94,400/118,000 96,000/120,000 50-80 80 80 76.9
48HJD006
50,000/ 72,000 40,000/ 57,100 41,000/ 59,040 15-45 82 82 78.7
48HJE006
82,000/115,000 65,600/ 92,000 66,420/ 93,150 35-65 81 81 77.8
48HJF006
120,000/150,000 94,400/118,000 96,000/120,000 50-80 80 80 76.9
48HJD007
50,000/ 72,000 — 41,000/ 59,040 15-45 82 82 78.7
48HJE007
82,000/115,000 — 66,420/ 93,150 35-65 81 81 77.8
48HJF007
120,000/150,000 — 96,000/120,000 50-80 80 80 76.9
Sizes 004-012
Only
Size 014 Only
UNIT
HEATING INPUT
(Btuh)
First Stage/Second Stage
OUTPUT CAPACITY
(Btuh)
First Stage/Second Stage
TEMPERATURE
RISE (
°
F)
AFUE
(%)
STEADY STATE
EFFICIENCY (%)
CALIFORNIA
SEASONAL
EFFICIENCY (%)
48HJD008
90,000/125,000 72,900/102,500 20-50 82 82 77.5
48HJE008
120,000/180,000 98,400/147,600 35-65 82 82 77.5
48HJF008
180,000/224,000 147,600/183,700 45-75 82 82 79.4
48HJD009
90,000/125,000 72,900/102,500 20-50 82 82 78.4
48HJE009
120,000/180,000 98,400/147,600 35-65 82 82 78.4
48HJF009
180,000/224,000 147,600/183,700 45-75 82 82 79.4
48HJD012
120,000/180,000 98,400/147,600 35-65 82 82 78.4
48HJD014, HJE012
180,000/224,000 147,600/183,700 35-65 82 82 79.3
48HJE014, HJF012
200,000/250,000 160,000/200,000 40-70 80 80 76.4
AFUE —
Annual Fuel Utilization Efficiency
ARI* capacities