1
T
RUCK REQUIREMENTS
GA0082.ill
GA0080.ill
Close Forks
Sideshift
Right
Tilt
Forward
Hoist Up
Auxiliary Valve Functions
Check for compliance with ITA (ISO) standards:
WARNING: Rated capacity of the truck/
attachment combination is a responsibility of the
original truck manufacturer and may be less
than that shown on the attachment nameplate.
Consult the truck nameplate.
Carriage
Clean carriage bars and inspect for
damaged notches
Tilt
Back
Hoist Down
Spread Forks
Sideshift
Left
GA0028.ill
Carriage Mount Dimension (A) ITA (ISO)
Minimum Maximum
Class II 14.94 in. (380.0 mm) 15.00 in. (381.0 mm)
Class III18.68 in. (474.5 mm) 18.74 in. (476.0 mm)
Class IV23.44 in. (595.5 mm) 23.50 in. (597.0 mm)
Truck Relief Setting
2000 psi (140 bar) Recommended
2300 psi (160 bar) Maximum
Truck Flow Volume
Min.
Recommended Max.
55C, 100C, 5 GPM 7 GPM 10 GPM
120C, 150C(19 L/min.) (26 L/min.) (38 L/min.)
Cascade C-Series Fork Positioners are compatible with SAE
10W petroleum base hydraulic fluid meeting Mil. Spec. MIL-0-
5606 or MIL-0-2104B. Use of synthetic or aqueous base
hydraulic fluid is not recommended. If fire resistant hydraulic
fluid is required, special seals must be used. Contact Cascade.
Flow less than recommended can result in slow and unequal
fork movement.
Flow greater than maximum can result in excessive heating,
reduced system performance and short hydraulic system life.
A

Other manuals for Cascade C Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cascade C Series and is the answer not in the manual?

Cascade C Series Specifications

General IconGeneral
BrandCascade
ModelC Series
CategoryForklifts
LanguageEnglish

Related product manuals