Electric Start
starting your generator
1. Make sure all appliances are disconnected from the generator.
2. Turn engine choke switch to the START (ON) position. (When the
engine is warm or temperature is high, start engine with the choke
switch in the “OFF” position).
3. Set the toggle switch to the middle “ON” position. Pres and hold the
toggle to the start position to engage the starter. Release, set toggle to
the “ON” position when engine is running.
1. After 20 to 30 seconds of warm-up is completed, turn the engine
choke switch to the “OFF” position.
2. Test the GFCI receptacle on the unit. Push the test button. The reset
button should pop out and there should be no power at the receptacle.
Apply a test load or lamp to each receptacle to verify. IF THE RESET
BUTTON DOES NOT POP OUT, DO NOT USE THE RECEPTACLE.
SEE SERVICE PROVIDER FOR SERVICE IMMEDIATELY.
3. If GFCI receptacle tests correctly, firmly push the reset button to
restore power. A distinctive click should be heard or felt when this is
complete. IF THE RECEPTACLE DOES NOT RESET PROPERLY, DO
NOT USE THE RECEPTACLE. SEE SERVICE PROVIDER FOR
SERVICE IMMEDIATELY.
4. Loads can now be applied to unit.
CAUTION
Do not connect appliances with defective power cords and/or plugs.
• Be sure appliances are not connected to generator when starting
up. Starting the generator with an appliance connected could result in
damage to the generator and/or appliances and personal injury.
• DO NOT turn the starting motor over 5 seconds continuously . If the
engine fails to start, return the toggle switch to the “ON” position and
wait about 10 seconds and then start again.
• DO NOT press the toggle switch to the “START” position when the
engine is running to prevent damage of starting motor.