– 23 –
Diagnostic program
1. Button check and Bender check
Press "1" button.
Press the button in the order indicated in the illustration below.
The button number will be displayed on the LCD.
Example) SW00 + (the button number shown in the illustration)
If the switch function is OK: You will hear the OK sound signal and the button number will be displayed.
If the switch function is NG or switches were pressed in a wrong order: You will hear the NG sound signal
and the button number will be displayed.
23
25
24
21
04
05
06
07
57
56
58
OK
08
20
0A
09
0E
0B
0C
0F
0D
10
11
12
13
22
26
02
01
00
1B
18
15
14
1C
19
16
1F
1D
1A
17
1E
03
When the Bender Check is completed, the display shown on
the right appears.
Press "0" to end the Button Check and Bender Check.
2. AC adaptor check
Press "3" button.
Make sure that a value "XXX" shown in the illustration is in
the range of 000 to 3FF.
Press "3" button.
Make sure that a value "XXX" shown in the illustration is in
the range of 000 to 1FF.