Step 8 Check the SSD LED to make sure the SSD is operative. See Front Panel LEDs for a description of the SSD LEDs.
Remove and Replace the Power Supply Module
Power supply modules are hot-swappable. You can remove and replace power supply modules while the
system is running.
Safety Warnings
Take note of the following power and component removal safety warnings:
Statement 1003—DC Power Disconnection
To reduce risk of electric shock or personal injury, disconnect DC power before removing or replacing
components or performing upgrades.
Warning
Statement 1005—Circuit Breaker
This product relies on the building’s installation for short-circuit (overcurrent) protection. To reduce risk
of electric shock or fire, ensure that the protective device is rated not greater than:
AC: 20A
DC: 40A
Warning
Statement 1017—Restricted Area
This unit is intended for installation in restricted access areas. Only skilled, instructed, or qualified
personnel can access a restricted access area.
Warning
Statement 1018—Supply Circuit
To reduce risk of electric shock and fire, take care when connecting units to the supply circuit so that
wiring is not overloaded.
Warning
Statement 1022—Disconnect Device
To reduce risk of electric shock and fire, a readily accessible two-poled disconnect device must be
incorporated in the fixed wiring.
Warning
Installation, Maintenance, and Upgrade
6
Installation, Maintenance, and Upgrade
Remove and Replace the Power Supply Module