Table 6 Available Plug-In PCIe Card RAID Options
Product ID (PID) PID Description
RAID Controllers
UCS-RAID-9266NB LSI MegaRAID SAS 9266-8i RAID controller card with no data cache backup
(RAID 0, 1, 10, 5, 6, 50, and 60 supported)
Installed by default in the half-height PCIe slot (slot 2)
Supports up to 16 internal SAS and/or SATA drives (limited to 12 drives for
the C240 M3 LFF chassis). SAS and SATA drives can be mixed.
Includes 1 GB of write cache
Factory-configured RAID options available: RAID 0, 1, 10, 5, and 6 (see the
RAID PIDs section in this table)
UCS-RAID-9266CV LSI MegaRAID 9266CV-8i RAID controller card with data cache backup (RAID 0,
1, 10, 5, 6, 50, 60)
Supports up to 16 internal SAS or SATA drives (limited to 12 drives for the
C240 M3 LFF chassis). SAS and SATA drives can be mixed.
Includes a 1 GB Transportable Memory Module (TMM) and SuperCap power
module for data cache backup
Factory-configured RAID options available: RAID 0, 1, 10, 5, and 6 (see the
RAID PIDs section in this table)
Battery Backup Option
UCS-RAID-CV-SC= LSI CacheVault Power Module for 9266CV-8i
RAID Configuration Options
R2XX-RAID0 Factory preconfigured RAID striping option
Enable RAID 0 Setting. Requires a minimum of one hard drive.
R2XX-RAID1 Factory preconfigured RAID mirroring option
Enable RAID 1 Setting. Requires exactly two drives with the same size, speed,
capacity.
R2XX-RAID5 Factory preconfigured RAID option
Enable RAID 5 Setting. Requires a minimum of three drives of the same size,
speed, capacity.
R2XX-RAID6 Factory preconfigured RAID option
Enable RAID 6 Setting. Requires a minimum of four drives of the same size,
speed, capacity.
R2XX-RAID10 Factory preconfigured RAID option
Enable RAID 10 Setting. Requires a even number of drives (minimum of four
drives) of the same size, speed, capacity.
NOTE: Although RAID levels 50 and 60 are not orderable from the factory, they are
supported for selected controllers as shown in Table 6

Other manuals for Cisco UCS C240 M3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco UCS C240 M3 and is the answer not in the manual?

Cisco UCS C240 M3 Specifications

General IconGeneral
Processor cores8
Processor modelE5-2600
Processor frequency2.7 GHz
Number of processors installed2
HDD size2.5 \
RAID supportYes
HDD interface-
Optical drive typeNo
Total storage capacity300 GB
Maximum storage capacity- TB
Number of HDDs installed16
Memory slots24
Internal memory96 GB
Memory clock speed1866 MHz
Internal memory typeDDR3-SDRAM
Maximum internal memory- GB
USB 2.0 ports quantityUSB 2.0 ports have a data transmission speed of 480 Mbps, and are backwards compatible with USB 1.1 ports. You can connect all kinds of peripheral devices to them.
PCI Express x8 slots3
Chassis typeRack (2U)
Power supply650 W
Operating altitude0 - 3000 m
Non-operating altitude0 - 12000 m
Operating temperature (T-T)-40 - 70 °C
Storage relative humidity (H-H)5 - 93 %
Operating relative humidity (H-H)10 - 90 %
Harmonized System (HS) code84714100
Weight and Dimensions IconWeight and Dimensions
Depth712 mm
Width445 mm
Height87 mm