EasyManuals Logo
Home>Cisco>Server>UCS C240 M3

Cisco UCS C240 M3 Manual

Cisco UCS C240 M3
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #22 background imageLoading...
Page #22 background image
Cisco UCS C240 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
22
CONFIGURING the SERVER
Approved Configurations
(1) No RAID controller plug-in card
If you did not choose a plug-in RAID controller (for example, you are using the mezzanine
RAID controller), you can select up to five PCie option cards listed in
Table 8.
(2) One RAID controller plug-in card
If you selected a plug-in PCIe RAID controller, you can select only one of the optional PCIe
cards listed in
Table 8.
Caveats
For 1-CPU systems:
Only the three PCIe slots on PCIe riser 1 are supported. The three slots are PCIe slots
1, 2, and 3 (see
Figure 2 on page 4). These are the three slots on the right when
looking at the rear of the server.
Neither the PCIe riser 2 (with the two PCIe slots numbered PCIe 4 and PCIe 5, at the
left when viewing the server from the rear) nor the mezzanine card are supported
on 1-CPU systems.
Only a single VIC card (a full-height PCIe card) may be installed on a 1-CPU system,
and it must be installed in slot 2. See
Table 1 on page 5 for the slot descriptions.
For 2-CPU systems:
Five PCIe slots are supported, three on PCIe riser 1 (PCIe slots 1, 2, and 3) and two
on PCIe riser 2 (PCIe slots 4 and 5).
All of the slots are full-height except one.
All of the server PCIe adapter cards are half-height cards, with the exception of the
Virtual Interface Card (VIC) (N2XX-ACPCI01), which is a full-height card. Therefore,
two VIC cards may be installed in 2-CPU systems, using slots 2 or 5. Note, however,
that if the server is using UCSM, only slot 2 is supported for the VIC card. See
Table 1 on page 5 for the slot descriptions.
All PCIe cards will fit in either slot, except the VIC card, which must be installed in a
full-height slot (slots 2 or 5, except only slot 2 when the server uses UCSM).
To help ensure that your operating system is compatible with the card you have selected,
check the Hardware Compatibility List at this URL:
http://www.cisco.com/en/US/products/ps10477/prod_technical_reference_list.html
NOTE: If a plug-in RAID controller card is installed, any optional PCIe card you select
will be installed in the full-height slot. RAID controllers are always installed in the
half-height slot.

Other manuals for Cisco UCS C240 M3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco UCS C240 M3 and is the answer not in the manual?

Cisco UCS C240 M3 Specifications

General IconGeneral
Processor cores8
Processor modelE5-2600
Processor frequency2.7 GHz
Number of processors installed2
HDD size2.5 \
RAID supportYes
HDD interface-
Optical drive typeNo
Total storage capacity300 GB
Maximum storage capacity- TB
Number of HDDs installed16
Memory slots24
Internal memory96 GB
Memory clock speed1866 MHz
Internal memory typeDDR3-SDRAM
Maximum internal memory- GB
USB 2.0 ports quantityUSB 2.0 ports have a data transmission speed of 480 Mbps, and are backwards compatible with USB 1.1 ports. You can connect all kinds of peripheral devices to them.
PCI Express x8 slots3
Chassis typeRack (2U)
Power supply650 W
Operating altitude0 - 3000 m
Non-operating altitude0 - 12000 m
Operating temperature (T-T)-40 - 70 °C
Storage relative humidity (H-H)5 - 93 %
Operating relative humidity (H-H)10 - 90 %
Harmonized System (HS) code84714100
Weight and Dimensions IconWeight and Dimensions
Depth712 mm
Width445 mm
Height87 mm

Related product manuals