INSTRUCTIONS FOR TECHNICAL PERSONNEL
12
INSTALLATION
During installation, carry-out a good machine levelling, which is a
prerequisite for a correct operation thereof. In order to prevent any damages
caused by vapours going out of the machine, make sure that the surrounding
materials don't deteriorate in their presence.
1)ELECTRICAL CONNECTION
The electrical power supply shall be fed to the machine by connecting it to a
wall-mounted differential magneto-thermal on/off switch, with a contact
aperture distance equal to or greater than 3 mm.
The said magnetothermal on/off switch should be rated according to the
following table, as a function of the power supply voltage, the machine
model, and the heating type (electrical or steam heating).
Modèle Type de
chauffage
Branchement
électrique (V)
Puissance
totale (kW)
Absorption
électrique (A)
Section câble
alimentation
(mm²)
Inter-
rupteur
a mur
(A)
GE605 RCD électrique
380-400V/3N
9 13,7 2,5 16.0
GE755 RCD électrique
380-400V/3N
9 13,7 2,5 16.0
GE805 RCD électrique
380-400V/3N
9 13,7 2,5 16.0
GE1005 RCD électrique
380-400V/3N
15 23,0 4 32.0
GE1255 RCD électrique
380-400V/3N
15 23,0 4 32.0
N.B.: Check that the voltage which the machine is set to correspond to the
power supply voltage available.
Power cable cross section must not be less then that indicated in the table. If
the cables are not protected by a sheathing, use a flexible, protected cable in
Polychloroprene with equivalent H07RN-F characteristics.
Check the line length; should it be too long, conform the line cross section to
such line length and to current drain; don't submit the power supply cable to
traction.
Cable must be connected to X1 terminal block passing through the cable
brake (see refer to electrical diagram).