Instructions
1. Set up and positioning
Adjusting the hose barb inlet and outlet
The hose barbs can be positioned in four different
locations to facilitate connections to other applications.
The Coralife Turbo-Twist Ultraviolet Sterilizers are easy to set up and operate.
Please read all instructions in their entirety before installation.
To accommodate your new sterilizer, you will need a power-head, pump, or canister filter
with an appropriate flow rate for the size of your UV Sterilizer to ensure adequate ultraviolet
exposure while treating the entire volume of aquarium water with appropriate frequency.
Unscrew locking ring screw and slide tab down to
release. (Picture 1)
Carefully twist the quartz housing and the main body
opposite of each other. (Picture 2)
Slide the quartz sleeve out of the main body. (Picture 3)
Reinstall locking ring and tighten screw.
QUARTZ
HOUSING
MAIN BODY
QUARTZ SLEEVE
QUARTZ
HOUSING
MAIN BODY
(PICTURE 1) (PICTURE 2) (PICTURE 3)
LOCKING ARM