Quick Start
The CCS-UC-1 W/PS, CCS-UC-1-AV W/PS, and CCS-UC-1-AV-PLUS are Unified Communications (UC) conference system solutions centered
around the CCS-UC-1 UC tabletop console. The CCS-UC-1 W/PS provides audio conference capabilities while the CCS-UC-1-AV W/PS and
CCS-UC-1-AV-PLUS add video capabilities to a conference room.
Check the Box
Item Qty
CCS-UC-1 W/PS , CCS-UC-1-AV W/PS, or CCS-UC-1-AV-PLUS 1
CCS-UC-1 Crestron Mercury® tabletop UC audio conference console 1
Cable, CAT5e, RJ-45 Male - RJ-45 Male, 12 ft (3.66 m) (P/N 2033988) 1
Cable, USB 2.0, A - Micro B, 6 ft (1.83 m) (P/N 2047803) 1
Retention Plate, Cable (P/N 2047908) 1
Power Pack, PW-2420RU (P/N 6500187) 1
Tie Wrap (P/N 2047935) 3
CCS-UC-1-AV W/PS
Cable, HDMI®, 6 ft (1.83 m), Thin, CBL-HD-THIN-HS-6 (P/N 6508218) 1
Cable, HDMI, 20 ft (6.10 m), CBL-HD-20 (P/N 6503567) 1
Cable, USB 2.0, A Female - A, 15 ft (4.57 m), CBL-USB-A-EXT-15 (P/N 6508260) 1
Camera, CCS-CAM-USB-F-100 (P/N 6506442) 1
IR Emitter Probe, STIRP (P/N 6500940) 1
CCS-UC-1-AV-PLUS
Cable, HDMI, 6 ft (1.83 m), Thin, CBL-HD-THIN-HS-6 (P/N 6508218) 1
Cable, HDMI, 20 ft (6.10 m), CBL-HD-20 (P/N 6503567) 1
Cable, USB 2.0, A Female - A, 15 ft (4.57 m), CBL-USB-A-EXT-15 (P/N 6508260) 1
Camera, CCS-CAM-USB-F-300 (P/N 6510481) 1
IR Emitter Probe, STIRP (P/N 6500940) 1
4-Port USB 3.0 Hub w/USB Power Adapter, UC-HUB-USB (P/N 6510546) 1
Install the Cable Retention Plate
Remove® the adhesive backing from the cable retention plate and install it as shown in the following diagram. The cable retention plate is designed
to fit at the cable exit location at the rear of the chassis and provides three tie-down points for cables connected to the device.
CAUTION: When turning over the device, place the device on a soft surface to avoid damage.
NOTE: If the CCS-UCA-SMK swivel mount kit is to be used, use the cable retention bracket included with the CCS-UCA-SMK. For details, refer to
the CCS-UCA-SMK DO Guide (Doc. 7882) at www.crestron.com/manuals.
CCS-UC-1
Install cable
retention
plate here
Cable retention
plate installed
NOTE: Before securing cables, ensure the cable retention plate is firmly attached.
Connect the Device
The CCS-UC-1 should be wired for its intended use. Refer to the following table to determine what is necessary for the specific installation.
Required Wiring Scenario
General Wiring Wiring with SMK Zoom Conference Room
Route cables through swivel tube plate No Yes Optional
Service loops Yes No Yes
Cable Retention Plate Yes Yes Yes
Feed Cables Through the Swivel Tube Plate (Installations with CCS-UCA-SMK only)
If the CCS-UCA-SMK swivel mount kit is used in the installation, refer to the CCS-UCA-SMK DO Guide (Doc. 7882).
NOTE: If the CBL-HD-THIN-HS-6, 6 ft HDMI input cable and the A - Micro B, 6 ft USB 2.0 cable are to be routed to the front of the CCS-UC-1, do
not route the cables through the swivel tube plate.
Hardware Hookup
When wiring the CCS-UC-1 to external devices, it is highly recommended to use the cables that ship with the device. Each kit ships with every cable
needed for most rooms. The cables and accessories have been designed so that a service loop can be implemented prior to the cables leaving the
chassis body of the device (if necessary). If an extension option is required, Crestron solutions should always be used and can be found under the
MODELS & ACCESSORIES tab at www.crestron.com/products/model/CCS-UC-1.
CCS-UC-1 W/PS
AUX:
10BASE-T/100BASE-TX
Ethernet to SIP
CCS-UCA-MIC Microphone pods (sold separately)
Must connect AC power pack to CCS-UC-1
Laptop
via included USB cable
USB/ACC:
For future use
Ground
100-240 V
50/60 Hz:
From ac
power outlet
24 Vdc, 2.5 A
AC power pack
Corporate
network
or PoE+
via included
Ethernet cable
LAN
CCS-UC-1-AV W/PS and CCS-UC-1-AV-PLUS
AUX:
10BASE-T/100BASE-TX
Ethernet to SIP
CCS-UCA-MIC Microphone pods
(sold separately)
Must connect AC power pack to CCS-UC-1
Laptop
via included USB cable
USB/ACC:
For future use
Ground
100-240 V
50/60 Hz:
From ac
power outlet
24 Vdc, 2.5 A
AC power pack
Corporate
network
or PoE+
via included
Ethernet cable
LAN
Display device
via CBL-HD-20
and IR or serial control
CCS-CAM-USB-F-100
(
CCS-UC-1-AV W/PS
only)
CCS-CAM-USB-F-300
(
CCS-UC-1-AV PLUS
only)
Connect with UC-HUB-USB
OR
CCS-UC-1 W/PS, CCS-UC-1-AV W/PS, CCS-UC-1-AV-PLUS
Crestron Mercury® Tabletop Unified Communications Conference System Solutions

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Crestron Mercury CCS-UC-1-AV W/PS and is the answer not in the manual?

Crestron Mercury CCS-UC-1-AV W/PS Specifications

General IconGeneral
BrandCrestron
ModelMercury CCS-UC-1-AV W/PS
CategoryConference System
LanguageEnglish

Related product manuals