EasyManuals Logo
Home>Crown>Amplifier>CL1

Crown CL1 User Manual

Crown CL1
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #27 background imageLoading...
Page #27 background image
Page 27
Contractor Series Power Amplifiers
Reference Manual
7 Specifications
Note: All measurements apply to all models of CH and CL series
amplifiers in stereo mode with 8-ohm loads and an input sensi-
tivity of 26-dB gain, 1-kHz at rated power unless other otherwise
specified. Specifications for units supplied outside the U.S.A.
may vary slightly at different AC voltages and frequencies.
Power
Load Impedance:
Safe with all types of loads.
CH1:
4 and 8 ohm Stereo;
16 ohm at 70V Stereo;
32 ohm at 100V Stereo;
8 and 16 ohm Bridge;
32 ohm at 140V Bridge;
64 ohm at 200V Bridge.
CH2:
4 and 8 ohm Stereo;
8 ohm at 70V Stereo;
16 ohm at 100V Stereo;
8 and 16 ohm Bridge;
16 ohm at 140V Bridge;
32 ohm at 200V Bridge.
CH4:
4 and 8 ohm Stereo;
4 ohm at 70V Stereo;
8 and 16 ohm Bridge;
8 ohm at 140V Bridge.
CL1, CL2 and CL4:
2, 4 and 8 ohm Stereo;
4, 8 and 16 ohm Bridge.
Voltage Gain, 1 kHz, 1.4V sensitivity,
CH1,
30.5 dB (4/8 ohm);
34 dB (70V);
37 dB (100V).
CH2,
32.1 dB (4/8 ohm);
34 dB (70V);
37 dB (100V).
CH4,
34 dB (4/8 ohm);
34 dB (70V).
CL1,
30.5 dB at (4/8 ohm).
CL2,
32.1 dB at (4/8 ohm).
CL4,
34 dB (4/8 ohm).
AC Line Requirements:
Note: North American CH 1, CL 1, CH 2 and CL 2
units are 60 Hz only. All other models are 50/60 Hz.
Voltages are ±10%.
AC Line Current,
CH 1 & CL 1:
100 Volts: 7.6 A;
120 Volts: 6.3 A;
230-240 Volts: 3.5 A.
CH 2 & CL 2:
100 Volts: 11.4 A;
120 Volts: 9.5 A;
230-240 Volts: 5.0 A.
CH 4 & CL 4:
100 Volts: 8.5 A;
120 Volts: 7.1 A;
230-240 Volts: 3.7 A.
AC Line Connector: Detachable 15A IEC connector
with country-specific plug.
Output Power:
(See Figure 7.1).
Performance
Frequency Response, 20 Hz to 20 kHz at 1 watt,
CH 1, CH 2, CL 1 & CL 2: ±0.1 dB (see Figures 7.2
and 7.3).
CH 4 & CL 4: ±0.25 dB (see Figure 7.4).
Phase Response: ±15 degrees from 20 Hz to 20 kHz
at 1 watt.
Signal to Noise Ratio, A-Weighted,
CH 1, CH 2, CL 1 & CL 2: Better than 105 dB below
rated 1-kHz power.
CH 4 & CL 4: Better than 102 dB below rated 1-kHz
power.
Total Harmonic Distortion (THD), 1 kHz at rated
power: 0.5% or less true THD from 20 Hz to 20 kHz.
Intermodulation Distortion (60 Hz and 7 kHz at
4:1): Less than 0.1% at rated power to 30 dB below
rated power at 8 ohms.
Damping Factor (8 ohm),
CH 1, CH 2, CL 1 & CL 2: Better than 400 from 10 Hz
to 400 Hz (see Figure 7.5).
CH 4 & CL 4: Better than 700 from 10 Hz to 400 Hz
(see Figure 7.6).

Table of Contents

Other manuals for Crown CL1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Crown CL1 and is the answer not in the manual?

Crown CL1 Specifications

General IconGeneral
BrandCrown
ModelCL1
CategoryAmplifier
LanguageEnglish

Related product manuals