Verifies continuity, insulation resistance, and differential protection for safe operation.
Specific terminal references for power supply, contactors, and pump connections.
Terminal functions for connecting pressure switches, floats, and level probes.
Terminals designated for connecting dry operation protection and associated alarm signals.
Terminals used for connecting pressure sensors that provide an analog input signal.
Terminals for receiving remote alarm signals from pumps and general alarm notifications.
Terminals that indicate the power status of pumps P1 and P2.
Controls and indicators for manual operation or deactivation of Pump P1.
Controls and indicators for manual operation or deactivation of Pump P2.
Adjusts the maximum current limit for pumps P1 and P2 using the Imax trimmer.
Sets system pressure (SP) and differential pressure (DP) using dedicated trimmers.
How the booster function works with sensors and different expansion vessel sizes.
How the booster function operates when using external pressure switches.
Sequence of operations for the filling function using two float switches.
Sequence of operations for the filling function using three float switches.
Operation of the filling function controlled by a sensor for tank level monitoring.
Sequence of operations for the draining function using two float switches.
Sequence of operations for the draining function using three float switches.
Operation of the draining function controlled by a sensor for tank level monitoring.
A table detailing alarm types, LED indicators, and remote signal contacts.
Explains how digital inputs R and N trigger alarms for various operational functions.
Triggers when the pressure sensor is incoherent, not detected, or its signal is out of range.
Alarm activated due to incorrect configuration of the internal dip-switches.
Details overcurrent protection, auto-reset attempts, and manual reset procedures.
Activation of dry running protection, including auto-resets and manual reset requirements.
Limits pump start frequency and indicates activation via a blinking yellow LED.
Alarms for phase loss or motor thermal protection (KK), with specific restart attempt logic.
Alarm triggered if control buttons are pressed during the initial 30 seconds of power supply.
Alarm indicating incorrect float/probe installation or malfunction leading to specific activation patterns.