5(63216,%,/,7<
The Manufacturer does not vouch for correct operation of the electro-
pumps or answer for any damage that they may cause if they have been
WDPSHUHG ZLWK PRGL¿HG DQGRU UXQ RXWVLGH WKH UHFRPPHQGHG ZRUN
range or in contrast with other indications given in this manual.
The Manufacturer declines all responsibility for possible errors in this instruc-
tions manual, if due to misprints or errors in copying. The Manufacturer re-
VHUYHVWKHULJKWWRPDNHDQ\PRGL¿FDWLRQVWRSURGXFWVWKDWLWPD\FRQVLGHU
necessary or useful, without affecting their essential characteristics
1. TECHNICAL CHARACTERISTICS
e.sybox HV\ER[
ELECTRIC POWER
SUPPLY
Voltage [a9$&
Frequency +]
Maximum current $ 6,8 A
Maximum power : :
CONSTRUCTION
CHARACTERI-
STICS
Overall dimensions 565x265x352 mm without feet
Empty weight (excluding
SDFNDJLQJ
NJ 22,5 kg
Protection class ,3[
Motor insulation class F
HYDRAULIC
PERFORMANCE
Maximum head
65 m P
0D[LPXPÀRZUDWH OPLQ OPLQ
Priming <5min at 8m <5min a 7m
WORKING
CONDITIONS
Maximum working pressure 8 bar
Liquid temperature max &
Environment temperature max &
Storage environment
temperature
·&
2. INSTALLATION
7KHV\VWHPLVGHVLJQHGIRULQGRRUXVHGRQRWLQVWDOOWKHV\VWHPRXWGRRUVDQG
or directly exposed to atmospheric agents.
The system is designed to be able to work in environments where the tem-
SHUDWXUHUHPDLQVEHWZHHQ&DQG&
The system is suitable for treating drinking water.
7KHV\VWHPFDQQRWEHXVHGWRSXPSVDOWZDWHUVHZDJHLQÀDPPDEOHFRUUR-
VLYHRUH[SORVLYHOLTXLGVHJSHWUROHXPSHWUROWKLQQHUVJUHDVHVRLOVRUIRRG
products.
The system can take in water the level of which must not be at a depth greater
WKDQPIRUHV\ER[DQGPIRUHV\ER[WKHKHLJKWEHWZHHQWKHZDWHU
OHYHODQGWKHSXPSVXFWLRQPRXWK
Do not connect any pipe to the 1¼’’ mouth that houses the non-return valve,
VHH¿J
If the system is used for the domestic water supply, respect the local regula-
tions of the authorities responsible for the management of water resources.
&KRRVLQJWKHLQVWDOODWLRQVLWHYHUL¿HGWKDW
The voltage and frequency on the pump’s technical data plate correspond
to the values of the power supply system.
The electrical connection is made in a dry place, far from any possible
ÀRRGLQJ
7KHHOHFWULFDOV\VWHPLVSURYYLGHGZLWKDGLIIHUHQWLDOVZLWFKZLWK,ǻQ
P$DQGWKDWWKHHDUWKV\VWHPLVHI¿FLHQW
3. COMMISSIONING
Maximum working pressure 8 bar.
7KHLQWDNHGHSWKPXVWQRWH[FHHGPIRUHV\ER[DQGPIRUHV\ER[
3.1 Electrical Connections
To improve immunity to the possible noise radiated towards other appliances it is rec-
ommended to use a separate electrical duct to supply the product.