EasyManuals Logo
Home>Daikin>Air conditioning>CDKD35CVM

Daikin CDKD35CVM User Manual

Daikin CDKD35CVM
298 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #264 background imageLoading...
Page #264 background image
Si12-411A Outdoor Unit (50 / 52 / 58 / 68 / 75 Class)
Removal Procedure 253
5
Take off the putty, and
remove each
thermistor.
Place the thermistor so that
its end comes up to the end
of the presser spring.
Be careful not to lose the
presser spring for the
discharge pipe thermistor.
6
Remove the wire
harness.
S90:
Outdoor air thermistor (Blue)
Heat exchanger thermistor
(Gray)
Discharge pipe thermistor
(Black)
S92: Gas pipe thermistor
Room A (Black)
Room B (Gray)
Room C (Brown)
Room D (Red)
S93: Liquid pipe thermistor
Room A (Black)
Room B (Gray)
Room C (Yellow)
Room D (Blue)
Step
Procedure Points

Table of Contents